Chapter 7
Troubleshooting the DPA 7630/7610
Interpreting LED Status
7-6
Cisco DPA 7630/7610 Voice Mail Gateways Administration Guide
78-11069-03
Interpreting LED Status
The DPA 7630/7610 includes several LED status indicators on the front panel
(see
Figure 7-1
).
Table 7-2
includes descriptions of these LEDs.
Voice mail hunt groups
containing more than 13
extensions can cause voice
mail access to fail with an
error tone.
By default, the Cisco CallManager
supports a maximum of 12
forwarding hops, leading to a
maximum of 13 extensions in any
one hunt group.
To avoid this error, do one of the
following:
•
Set the hop count system
parameter to more than 12.
•
Divide the DPA 7630/7610 into
several hunt groups (possibly all
in the same forwarding chain) to
improve load balance.
Refer to the
“Setting Up the
Voice Mail Hunt Group” section
on page 4-5
.
Table 7-1
DPA 7630/7610 Troubleshooting Suggestions (continued)
Symptom
Solution
For More Information
Table 7-2
LED Status Explanation
LED
On
Flashing
Off
Power
Power connected and
operating normally
N/A
Power not connected
Status
Operating normally
Potential hardware error
detected.
Check the event log for
details.
Not operating normally
TX
N/A
Packet transmitted.
Nothing transmitted
RX
N/A
Packet received.
Nothing received
100 MBPS
Connected at 100 Mbps
N/A
Connected at 10 Mbps or
not connected