3.4 ADVISE AND CARE DURING THE INSTALLATION
- The Identification plate attached to the rear panel
contains information about the serial number, the
type of machine, the necessary power supply and
the absorbed current.
- Before switching the machine on be sure that all
the cables have been connected correctly and
that the local power supply corrisponds to that
stated on the plate. The plate layout is as follows:
(ref. figure 3.4).
After the Trade name the plate has 6 embossed fields
as shown below:
Model : Machine model
Type:
Type of machine
Vnom:
Power Supply
Hz:
Frequency supply
Imax:
Power absorbed
SN:
Serial Number
- If the tension of the power supply should exceed
a 20% increase of the base tension the safety fast-
blow fuses could open. In order to substitute it take
a flat blade screw driver, remove the power plug
and place the blade in the nitch at the bottom of
the plug entrance just above the signed area for
the fuse. Gently lever the Fuse Block until it can be
removed by hand
REPLACE ONLY WITH FUSE OF THE
SAME TYPE AND RATED
- In order to garantee a correct functioning of the
machine and offer a valid safety level to the
operator the machine must be
earthed
. Please
ensure that the Stamper is connected to a power
supply that has a good earthing and that the
computer is also connected to the same line.
WARNING! USE ONLY LISTED
DETACHABLE POWER SUPPLY
CORD NOT EXCEEDING 4.6 M
LENGHT, 18 AWG RATED 10 A
PROVIDED WITH EARTH PROTECTIVE
CONDUCTOR.
- The electrolock enables the working mode for the
Technician and should be used only by those
specialised persons who have been authorised to
deal with the maintenance and the reparations.
Connect the appropriate cable with the plug
type Cannon 25/9 pin to the serial socket of the
computer and control the conection to the serial
ports
COM1
,
COM2
in order to report the correct
information when configuring the Software.
NOTE: CONNECT THIS CABLE WHEN
THE STAMPER HAS BEEN SWITCHED
OFF.
REV. 05-2008
Содержание MDM 1000
Страница 1: ......
Страница 5: ...0 5 METAL DOT MATRIX 0 FOREWORD...
Страница 6: ...0 6 METAL DOT MATRIX REV 04 2002 0 FOREWORD OPERATORS MANUAL REV 05 2008...
Страница 9: ...1 9 METAL DOT MATRIX GENERAL INFORMATION 1...
Страница 19: ...2 19 METAL DOT MATRIX UNPACKING 2...
Страница 21: ...3 21 METAL DOT MATRIX INSTALLATION 3...
Страница 27: ...4 27 METAL DOT MATRIX OVERALL DESCRIPTION 4...
Страница 33: ...5 33 METAL DOT MATRIX HOW TO PRODUCE ONE CARD 5...
Страница 43: ...6 43 METAL DOT MATRIX MAINTENANCE 6...
Страница 47: ...7 47 METAL DOT MATRIX TROUBLESHOOTING 7...
Страница 73: ...B 73 METAL DOT MATRIX HOW TO UPDATE THE FW ANNEX B...
Страница 77: ...C 77 METAL DOT MATRIX LCD EDIT ANNEX C...
Страница 99: ......