Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
3-50
DELAY TIME
CV MODE
CC MODE
Time
FOLDBACK
PROTECTION
DC SOURCE OPERATION MODE
Figure 3-87
Assuming the FOLDBACK is set to CV TO CC, the solid line in Figure 3-87 will create
Foldback protection while the dotted line will not.
3.
Press “
ENTER
” to confirm.
4.
Press
“
EXIT
” to return to the MAIN PAGE.
3.3.5.8
OTP
The OTP protection will activate when the internal temperature reaches the high limit and the
output will be turned off that is OUTPUT = OFF for protection.
When OTP occurs the main page will prompt a protection message as Figure 3-88 shows:
V = 6 0. 0 0 V I = 1 0. 0 0 _ A O F F
0 . 0 0 0 0 V 0 . 0 0 0 0 A
O T P 0 . 0 W
Figure 3-88
1.
User is unable to change the OTP setting.
2.
The output will turn off when OTP occurs and won’t be on again that
is OUTPUT = OFF until the internal temperature drops to a certain
set value.