Installation
2-3
2.2.1
Normal Environment Conditions
(1) In door use.
(2) Altitude up to 2000 meters.
(3) Temperature 0
C to 40
C.
(4) Maximum relative humidity is 65% at 25
C and increasing linearly to 90% relative
humidity for temperature up to 40
C.
(5) Input AC power voltage fluctuations can be up to
10% of the rated voltage.
(6) Transient over voltage is impulse withstand CAT II.
(7) Pollution degree II.
2.3
Requirements of Input Power
2.3.1
Ratings
(1) Model 62050H-xxxxS
Maximum input power: 12 kVA
(2) Model 62100H-xxxxS
Maximum input power: 21 kVA
(3) Model 62150H-xxxxS/A620027/A620028
Maximum input power: 29 kVA
(4) Model 62020H-150S:
Maximum input power: 2.9 kVA
Vin
62050H-xxxxS 62100H-xxxxS 62150H-xxxxS
A620027
A620028
62020H-150S
200/220
39A
69 A
93 A
Current
of each
phase
380/400
22A
37 A
50 A
440/480
19A
32 A
44 A
200/240
15.2 A
2.3.2
Input Connection
(1) The input connector board is located at the right of the rear panel.
(2) The power line must be 85°C rated at least.
(3) The power cable width must be within 6AWG~8AWG. (Note: 10AWG~12AWG is
required for Model 62020H-150S.)
(4) See Figure 2-3 (a), (b) to assemble 62000H and Figure 2-5 to assemble Model
62020H-150S. Execute the following steps:
a.
Remove the input terminal safety cover from the rear panel of DC Power Supply.
b.
Scrape off the skin of power cable tip (the bare portion is about 1cm) and use an O
type terminal to crimp it. (For Model 62020H-150S, the bare portion needs to be
tinned.)
c.
Secure the power cable and input terminal with a Phillips screwdriver. The
suggest range for lock torque is 30~40 (kg-cm). (For Model 62020H-150S, insert
the power terminal and use a Phillips screwdriver to secure it.)
d.
Lock the safety cover to avoid electric shock.
Model