Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-28
8.
CONFigure:APGISet
Description:
It sets the action type of APG ISET.
Syntax:
CONFigure:APGISet NONE
CONFigure:APGISet VREF5
CONFigure:APGISet RREF
Parameter:
NONE | VREF5 | VREF10 | IREF | RREF
Example:
CONFigure:APGISet VREF10
Query Syntax:
CONFigure:APGISet?
Query Example: CONFigure:APGISet?
Return Example: VREF10
9.
CONFigure:APGIMeas
Description:
It sets the action type of APG IMEAS.
Syntax:
CONFigure:APGIMeas NONE
CONFigure: APGIMeas VREF5
CONFigure: APGIMeas IREF
Parameter:
NONE | VREF5 | VREF10 | IREF
Example:
CONFigure:APGIMeas VREF10
Query Syntax:
CONFigure:APGIMeas?
Query Example: CONFigure:APGIMeas?
Return Example: VREF10
10. CONFigure:AVG:TIMES
Description:
It sets the average times of measurement for input voltage/current.
Syntax:
CONFigure:AVG:TIMES <NR1>
Parameter:
<NR1>
0: 1 time
1: 2 times
2: 4 times
3: 8 times
Example:
CONFigure:AVG:TIMES 0
CONFigure:AVG:TIMES 1
Query Syntax:
CONFigure:AVG:TIMES?
Return Parameter: 1 |2 | 4 | 8
Query Example:
CONFigure:AVG:TIMES?
Return Example: 1
11. CONFigure:AVG:METHod
Description:
It sets the average method of AD for input voltage/current.
Syntax:
CONFigure:AVG:METHOD <NR1>
Parameter:
FIX/MOV
Example:
CONFigure:AVG:METHOD FIX
CONFigure:AVG:METHOD MOV
Query Syntax:
CONFigure:AVG:METHOD?
Return Parameter: FIX | MOV
Query Example:
CONFigure:AVG:METHOD?
Return Example: FIX
12. CONFigure:BRIGhtness
Description:
It sets the display brightness of panel.
Description:
CONFigure:BRIGhtness
CONFigure: BRIGhtness DIM
Parameter:
HIGH | NOR | DIM