Manual Operation
3-29
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E = M A S T E R
M / S T E R M I N A T O R
= D I S A B L E
P A R A L L E L O R S E R I E S
= P A R A L L E L
N U M . O F S L A V E
= 4 _
M A S T E R & S L A V E C O N T R O L = N O
Figure 3-43
3.
Press “
ENTER
” to confirm.
4.
Press “
EXIT
” to return to the MAIN PAGE.
Take example by 62150H-600S:
1.
If there are 5 sets connected in parallel and 600V/100A is set, the
setting of each set is 600V/20A and the total output will be
600V/100A.
2.
If there are 2 sets connected in series and 1200V/25A is set, the
setting of each set is 600V/25A and the total output will be
1200V/25A.
3.
The total sets for connecting in series are 2; therefore, the
maximum number of NUM. OF SLAVE is 1.
4.
The total sets for connecting in parallel are 10; therefore, the
maximum number of NUM. OF SLAVE is 9.
3.3.3.3.5
Activating MASTER & SLAVE CONTROL
When PARALLEL OR SERIES, NUM. OF SLAVE are set for MASTER, it is able to use
MASTER to activate the series/parallel control as described below:
1.
Use “
”, “
” keys to move the cursor to the column to be set as Figure 3-44
shows.
2. Use the numeric (
1
) key or “Rotary” (
) knob to set YES
。
[ S E R I E S / P A R A L L E L ]
M A S T E R O R S L A V E = M A S T E R
M / S T E R M I N A T O R
= D I S A B L E
P A R A L L E L O R S E R I E S
= P A R A L L E L
N U M . O F S L A V E
= 4
M A S T E R & S L A V E C O N T R O L = Y E S _
Figure 3-44