- 5 -
3. Model code list
KP2
④
⑤
⑥
⑦
⑧
⑨
⑩
-
⑫
⑬
⑭
④
Input signal
⑨
Additional specifications of zone 2*
0 : Universal input
0 : None
4 : 4-wire resistance thermometer
J : Transmission signal output, output 2 (General type: 4-20mA)
Ú
3
⑤
Control mode (Output 1)
K : Transmission signal output, output 2 (General type: 0-1V)
Ú
3
1 : ON-OFF pulse type PID
L : Transmission signal output, output 2 (General type: 0-10V)
Ú
3
2 : ON-OFF servo type PID (Standard specifications)
H : Transmitter power supply
Ú
4
3 : Current output type PID
⑩
Zone 3*
5 : SSR drive pulse type PID
0 : None
6 : Voltage output type PID
R : Communication 1 port (RS232C) + 3 external signal inputs
8 : ON-OFF servo type PID (Very little load specifications)
A : Communication 1 port (RS422A) + 1 external signal input
⑥
Control mode (Output 2)*
S : Communication 1 port (RS485) + 3 external signal inputs
0 : None
B : Communication 2 port ( RS232C) + 1 external signal input
1 : ON-OFF pulse type PID
Ú
1
C : Communication 2 port ( RS422A) + 1 external signal input
3 : Current output type PID
Ú
1
D : Communication 2 port ( RS485) + 1 external signal input
5 : SSR drive pulse type PID
Ú
1
E : Communication 2 port (RS485 + RS232C) + 1 external signal input
6 : Voltage output type PID
Ú
1
F : Communication 2 port (RS485 + RS422A) + 1 external signal input
⑦
Zone 1*
G : Communication 2 port (RS485+RS485) + 1 external signal input
0 : None
9 : Heater snapping wire alarm
Ú
2
9 : Heater snapping wire alarm
P : External signal input 6 points
P : External signal input 6 points
M : External signal input 4 Heater snapping wire alarm
Ú
2
M : External signal input 4 Heater snapping wire alarm
Ú
2
T : External signal output 6 points
T : External signal output 6 points
N : External signal output 4 Heater snapping wire alarm
Ú
2
N : External signal output 4 Heater snapping wire alarm
Ú
2
U : External signal input 8 points
⑧
Zone 2*
V : External signal input 6 Heater snapping wire alarm
(2
0 : None
W : External signal output 8 points
1 : Transmission signal output (
High performance type
: 4-20mA)
X : External signal output 6 Heater snapping wire alarm
Ú
2
2 : Transmission signal output
(High performance type
:0-1V)
Y : External signal input 3 External signal output 5 points
3 : Transmission signal output (
High performance type
:0-10V)
Z : External signal input 4 External signal output 4 points
4 : Transmission signal output (
High performance type
: Others)
⑫
Case color
J : Transmission signal output (General type:4-20mA)
G : Gray
K : Transmission signal output (General type:0-1V)
B : Black
L : Transmission signal output (General type:0-10V)
⑬
IP54 panel sealing specifications and terminal cover*
9 : Heater snapping wire alarm
Ú
2
0 : None
P : External signal input 6 points
1 : Terminal cover exists
M : External signal input 4 Heater snapping wire alarm
Ú
2
2 : IP54 panel sealing specific No terminal cover
T : External signal output 6 points
3 : IN54 panel sealing specific Terminal cover
N : External signal output 4 Heater snapping wire alarm
Ú
2
⑭
Power supply voltage
A : 100-240V(AC)
D : 24V(AC/DC)
*
Option
Ú
1: It can be selected when control mode (output number 1) is 1, 3, 5, or 6.
Ú
2: It can be selected when control mode (output number 1) or control mode (output number 2) is 1 or 5 (pulse type).
Heater snapping wire alarm cannot overlap with other zones.
When output 1 and output 2 are both pulse type, alarm is judged output 1 side.
Ú
3: It can be selected when zone 2 is 1, 2, 3, or 4.
Ú
4: It can be selected when zone 2 is 0, 1, 2, 3, 4, J, K, or L
Note: Common options of zone 1,2,3 are designated form zone 3 ordering [9], [P], [M]
Содержание KP 2000 Series
Страница 1: ...INST No INE 809A Digital Program Controller KP2000 General ...
Страница 2: ......
Страница 143: ......