Appendix
Appendix 1 Typical Measurement Example
328
Appendix
●
Appendix 1 Typical Measurement Example
·····································································
●
Appendix 2 Time Domain Measurement
·········································································
●
Appendix 3 Frequency Offset Measurement
·····································································
●
Appendix 4 Pulse Measurement
··················································································
●
Appendix 5 Amplifier Gain Compression Measurement
·······················································
●
Appendix 6 Mixer Measurement
·················································································
Appendix 1 Typical Measurement Example
●
Startup, Preheating for 30min and Resetting of Analyzer
·······················································
●
Frequency and Power Setting
·····················································································
●
Selection of Measurement Parameter and Creating of New Trace
·············································
●
Calibration
●
Connection of DUT
································································································
●
Scale Adjustment and Data Analysis
·············································································
●
Recording or Saving of Data
······················································································
AV3672 series vector network analyzers are provided with various options and measurement settings are complex.
Technological knowledge and practical experience are required to be skillful in operation of the instrument. In
order to help you rapidly get familiar with the measurement process, the measurement attenuator is taken as an
example below to introduce the process and relevant settings for measurement of ordinary double-port devices.
Refer to Appendix 5 “Measurement of Amplifier Gain Compression” for the measurement of amplifier gain
compression and Appendix 6 “Mixer Measurement” for the measurement of the mixer.
Preparation before measurement: one AV3672 series vector network analyzer, two 3.5mm test cable, one
calibration kit (AV31121), DUT (attenuator) and adapter (if necessary).
1.1 Startup, Preheating for 30min and Resetting of Analyzer
Reset into the system reset state to ensure all settings are known.
1.2 Frequency and Power Setting
For more details, refer to “
4.3 Setting of Frequency Range
” and “
4.4 Setting of Signal Power Level
”.
Click [Freq] and [Power] on the front panel and [Modify] in the auxiliary menu bar. Enter the value through
the input keys on the front panel. Click ENTER. Thus setting is completed.
See the following figure:
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...