![China Electronics Technology Instruments AV3672 Series Скачать руководство пользователя страница 162](http://html1.mh-extra.com/html/china-electronics-technology-instruments/av3672-series/av3672-series_user-manual_2601790162.webp)
5 Menu
5.2. Description of menu
158
Smoothing
IF bandwidth
1) Restart Average
Function description:
Select this menu for a group of new average sweep.
Parameter description:
None
2) Average factor
Function description:
Select this menu to set the average times of curve sweep.
Set and adjust the parameter by the mouse/keyboard or the knob, number keys and stepping keys on the front panel.
Parameter description:
1[1~1024].
3) Average ON/OFF
Function description:
Select this menu to open the trace averaging function.
The more times averaging is done, the more noise will be reduced, and the larger the dynamic range will be.
The noise reduction effect of sweep averaging is the same as that of reduction of the intermediate frequency
bandwidth.
Parameter description:
OFF [OFF|ON].
4) Smoothing
This menu is used for smoothing setting. Click it to enter the menu of lower level. The specific menu includes:
Table 5.17 Smoothing
Menu
Smoothing ON/OFF
Smoothing percentage
Number of smoothing points
a) Smoothing ON/OFF
Function description:
Select this menu to enable the smoothing function.
The smoothing function is used to reduce the peak-peak noise of bandwidth measurement data.
Data averaging is done for part of the displayed trace. The number of adjacent data points averaged at the same
time is also known as the smoothing aperture. The aperture can be defined as the number of data points or the
percentage of X-axis span.
Parameter description:
OFF [OFF|ON].
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...