Appendix 6 Mixer Measurement
396
Fig. 6.19 Two-way Amplitude and Phase Response
ii. If the input frequency range and output frequency range are overlapped, the input/output isolation of the mixer
should be at least 1dB higher than the frequency transformation loss of the frequency overlapping part.
iii. The filter at the output end of the calibration mixer must be able to filter unnecessary mixing products and
ensure the passing of required mixing products.
c) Direction of calibration mixer/filter and reference mixer
The direction of the reference mixer is always the same as that of the tested mixer to ensure that the output
frequency is the same as that of DUT. The calibration mixer/filter can be used as the LO source at the upper and
lower transformation frequency. The internal source 2 can be used as the LO signal.
2) Establishment of vector mixer measurement
a) By the front panel: press [Meas] >
[Measurement Class]
.
b) Select
[Vector mixer measurement]
and click
[Delete current measurement]
. Then click
[New Channel]
to
establish the measurement in a new channel.
c) Set one VC21 measurement. The completion prompt will be displayed.
d) To add other parameters, click
[Trace] > [New Trace]
. Select one parameter from the list.
3) Parameters of vector mixer measurement
The DUT input end is generally connected to Port 1, and the DUT output end can be connected to any port.
a) VC21 VC31 and VC41: transformation loss or gain in the default mode, indicating the input end stimulus and
output end response.
b) S11: input end stimulus and response.
c) S22, S33 and S44: output end stimulus and response.
d) R1 or R: input end stimulus, and absolute power (not corrected) measured at the receiver end R1.
e) B, C and D: input end stimulus, and absolute power (not corrected) measured at the output end.
4) Setting of vector mixer calibration measurement
Menu path:
By the front panel: click
[Frequency] > [Mixer]
.
By the mouse: click
[Stimulus] > [Frequency] > [Mixer]
.
The following dialog box will appear on the screen. The mixer settings are the same as the scalar mixer settings.
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...