Appendix
Appendix 6 Mixer Measurement
383
Appendix 6 Mixer Measurement
●
Overview of mixer measurement
·················································································
●
Scalar mixer measurement
························································································
●
Calibration of scalar mixer measurement
········································································
●
Vector mixer measurement
························································································
●
Calibration of vector mixer measurement
········································································
6.1 Overview of Mixer Measurement
Mixer measurement mainly includes scalar and vector measurement.
6.1.1 Comparison of Scalar/Vector Mixer Measurement
Schedule 6.1 Comparison of Scalar/Vector Mixer Measurement
Scalar Measurement
Vector Measurement
Overall
comparison
➢
High
accuracy
of
frequency
transformation
gain
and
loss
measurement
➢
Optional for phase measurement.
➢
SOLT and power calibration
➢
Simpler than vector measurement
➢
High accuracy of phase and group delay
measurement
➢
Require the combination of SOLT calibration and
interchangeable mixer/filter in calibration
➢
Complete setting and calibration procedures
➢
Easy converter measurement after calibration
Measurement
➢
Support forward and backward
measurement.
➢
The DUT can be connected to any
port of the vector network analyzer.
➢
Amplitude response VC21
➢
Phase response
➢
Group delay
➢
The input end of the DUT must be connected to
Port 1 of the analyzer.
➢
The output end of the DUT can be connected to
any port of the analyzer.
Equipment
requirements
➢
Power meter and probe
➢
Reference mixer
➢
Calibration mixer/filter pair (S21=S12)
Mechanical or electronic calibration kit
6.1.2 Measurement Limitations
Prompt
Mixer measurement is not applicable in the following cases.
➢
Analog frequency canning
➢
Logarithmic frequency sweep
➢
Non-ratio reception measurement
➢
Electronic calibration described by the user.
➢
Time domain
➢
Balance measurement
➢
Port extension
➢
Some fixture features
➢
External test setting
Содержание AV3672 Series
Страница 1: ...AV3672 Series Vector Network Analyzer User Manual China Electronics Technology Instruments Co Ltd...
Страница 3: ......
Страница 4: ...AV3672 Series Vector Network Analyzer Contents...
Страница 5: ......
Страница 124: ...5 Menu 5 1 Menu structure 120 5 1 2 Track Fig 5 2 Track Menu...
Страница 125: ...5 Menu 5 1 Menu structure 121 5 1 3 Channel Fig 5 3 Channel Menu...
Страница 126: ...5 Menu 5 1 Menu structure 122 5 1 4 Excitation Fig 5 4 Excitation Menu I...
Страница 127: ...5 Menu 5 1 Menu structure 123 Fig 5 5 Excitation Menu II...
Страница 128: ...5 Menu 5 1 Menu structure 124 Fig 5 6 Excitation Menu III...
Страница 129: ...5 Menu 5 1 Menu structure 125 5 1 5 Response Fig 5 7 Response Menu I...
Страница 130: ...5 Menu 5 1 Menu structure 126 Fig 5 8 Repsonse Menu II...
Страница 131: ...5 Menu 5 1 Menu structure 127 Fig 5 9 Response Menu III...
Страница 132: ...5 Menu 5 1 Menu structure 128 Fig 5 10 Response Menu V Fig 5 11 Response IV...
Страница 133: ...5 Menu 5 1 Menu structure 129 5 1 6 Calibration Fig 5 12 Calibration Menu...
Страница 134: ...5 Menu 5 1 Menu structure 130 5 1 7 Marker Fig 5 13 Cursor Menu I...
Страница 135: ...5 Menu 5 1 Menu structure 131 Fig 5 13 Cursor Menu II...
Страница 136: ...5 Menu 5 1 Menu structure 132 Fig 5 15Marker Menu III...
Страница 137: ...5 Menu 5 1 Menu structure 133 5 1 8 Analysis Fig 5 16 Analysis Menu I...
Страница 138: ...5 Menu 5 1 Menu structure 134 Fig 5 17 Analysis Menu II...
Страница 139: ...5 Menu 5 1 Menu structure 135 Fig 5 18 Analysis Menu III...
Страница 140: ...5 Menu 5 1 Menu structure 136 5 1 9 System Fig 5 19 System Menu I...
Страница 141: ...5 Menu 5 1 Menu structure 137 Fig 5 20 System Menu I...
Страница 254: ...8 Basis of Network Measurement 8 3 Amplifier Parameter Specifications 250...
Страница 257: ...8 Basis of Network Measurement 8 4 Complex Impedance 253...
Страница 366: ...Appendix Appendix 3 Frequency Offset Measurement 362 Fig 3 13 Test of Return Loss of Mixer LO Port...
Страница 373: ...Appendix Appendix 4 Pulse Measurement 369 Fig 4 9 Receiver gain configuration Dialog Box...