26
Table 39 — Motor Limitations
LEGEND
NOTES:
1. Extensive motor and electrical testing on the Carrier units has ensured that
the full horsepower range of the motor can be utilized with confidence.
Using the fan motors up to the horsepower ratings shown in the Motor Lim-
itations table will not result in nuisance tripping or premature motor fail-
ures. Unit warranty will not be affected.
2. All motors comply with Energy Policy Act (EPACT) Standards effective
October 24, 1997.
Table 40A — Air Quantity Limits (48AJ,AK,AW,AY,A2,A3,A4,A5)
LEGEND
* Sizes 036,041, and 051 are 48AJ,AK,AW,AY only.
NOTE: Variable air volume units will operate down to 70 cfm/ton in Cooling
mode. Performance at 70 cfm/ton is limited to unloaded operation and may be
also limited by edb (entering dry bulb) and ewb (entering wet bulb) conditions.
HIGH-EFFICIENCY MOTORS
Nominal
Maximum
Maximum Amps
Maximum
Watts
Maximum
Efficiency
Bhp
BkW
Bhp
BkW
230 v
460 v
575 v
5
3.73
5.9
4.40
15.0
7.9
6.0
5,030
87.5
7.5
5.6
8.7
6.49
23.5
—
—
7,717
84.1
9.5
7.09
—
12.0
10.0
8,008
88.5
10
7.46
10.2
7.61
31.0
—
—
9,502
89.5
11.8
8.80
—
15.0
12.0
9,836
89.5
15
11.19
15.3
11.41
46.0
—
—
12,543
91.0
18.0
13.43
—
22.0
19.0
14,756
91.0
20
14.92
22.4
16.71
60.0
—
—
18,363
91.0
23.4
17.46
—
28.7
23.0
19,183
91.0
25
18.65
28.9
21.56
73.0
—
—
23,511
91.7
29.4
21.93
—
37.4
28.4
23,918
91.7
30
22.38
35.6
26.56
91.0
—
—
28,742
92.4
34.7
25.89
—
43.8
36.3
28,015
92.4
40
29.84
42.0
31.33
110.0
55.0
43.8
33,690
93.0
PREMIUM-EFFICIENCY MOTORS
Nominal
Maximum
Maximum Amps
Maximum
Watts
Maximum
Efficiency
Bhp
BkW
Bhp
BkW
230 v
460 v
5
3.73
5.9
4.40
15.8
7.9
4,918
89.5
7.5
5.6
8.7
6.49
23.5
—
7,078
91.7
9.5
7.09
—
12.0
7,728
91.7
10
7.46
10.2
7.61
30.0
—
8,298
91.0
11.8
8.80
—
15.0
9,600
91.7
15
11.19
15.3
11.41
46.0
—
12,273
91.7
18.0
13.43
—
22.0
14,439
93.0
20
14.92
22.4
16.71
59.0
—
17,853
93.0
23.4
17.46
—
28.7
18,650
93.6
25
18.65
28.9
21.56
73.0
—
23,034
93.6
29.4
21.93
—
36.3
23,432
93.6
30
22.38
35.6
26.56
82.6
—
28,374
93.6
34.7
25.89
—
41.7
27,656
93.6
40
29.84
42.0
31.33
110.0
55.0
33,156
94.5
Bhp
—
Brake Horsepower
BkW
—
Brake Kilowatts
UNIT SIZE*
MINIMUM HEATING
AIRFLOW CFM
(Low Heat)
MINIMUM HEATING
AIRFLOW CFM
(High Heat)
MINIMUM COOLING
AIRFLOW (VAV) CFM
AT FULL LOAD
MINIMUM COOLING
AIRFLOW CFM
(CV)
MAXIMUM AIRFLOW
CFM
020
5,900
6,100
4,000
6,000
10,000
025
5,900
6,100
5,000
7,500
12,500
027
5,900
6,100
5,400
8,100
13,500
030
5,900
6,100
6,000
9,000
15,000
035 (AJ,AK,AW,AY)
5,900
6,100
7,000
10,500
17,500
035 (A2,A3,A4,A5)
5,900
10,100
7,000
10,500
17,500
036,040,041
7,600
10,100
8,000
12,000
20,000
050
7,600
10,100
10,000
15,000
22,500
051,060
11,000
10,100
12,000
18,000
27,000
CV
—
Constant Volume
VAV
—
Variable Air Volume
Содержание WEATHERMAKER 48/50AJ
Страница 103: ...103 Fig 15 Typical Main Control Box Wiring Schematic 48 50AJ AK AW AY Units cont a48 8355 ...
Страница 104: ...104 Fig 16 Typical Main Control Box Wiring Schematic 48 50A2 A3 A4 A5 Units a48 8355 ...
Страница 105: ...105 TO NEXT PAGE Fig 17 Typical Auxiliary Control Box Wiring Schematic A48 7294 ...
Страница 106: ...106 Fig 17 Typical Auxiliary Control Box Wiring Schematic cont a48 8356 ...
Страница 107: ...107 Fig 18 Typical 2 Stage Gas Heat Wiring Schematic Size 051 and 060 Units Shown a48 8357 ...
Страница 108: ...108 TO NEXT PAGE Fig 19 Typical Staged Gas Heat Wiring Schematic Size 051 and 060 Units Shown A48 7296 ...
Страница 109: ...109 Fig 19 Typical Staged Gas Heat Wiring Schematic Size 051 and 060 Units Shown cont A48 8358 ...
Страница 110: ...110 Fig 20 Typical Electric Heat Control Schematic 50 Series Size 051 and 060 Units Shown a50 8228 ...
Страница 111: ...111 TO NEXT PAGE Fig 21 Typical Power Schematic 48 50AJ AK AW AY051 and 060 Units Shown A48 7298 ...
Страница 112: ...112 FROM PREVIOUS PAGE Fig 21 Typical Power Schematic 48 50AJ AK AW AY051 and 060 Units Shown cont a48 8360 ...
Страница 113: ...113 Fig 22 Typical Power Schematic 48 50A2 A3 A4 A5060 Unit Shown ...
Страница 114: ...114 SW1 SW2 OR DEHUMIDIFY SWITCH Fig 23 Typical Controls Option Wiring Schematic a48 8361 ...
Страница 115: ...115 Fig 24 Typical Small Chassis Component Location Size 020 035 Units a48 8362 ...
Страница 116: ...116 Fig 25 Typical Large Chassis Component Locations Size 036 060 Units A48 7302 ...
Страница 169: ...169 APPENDIX C VFD INFORMATION cont Fig F Internal Enclosure Fan Replacement A48 7716 ...