set
set (ocudp) baud
Use the set (ocudp) baud command to configure the Baud Rate for OCU-DP ports.
Syntax:
set {ocudp-addr} baud {rate}[sw56|sw56cp]
Example:
set 3:2 baud 2400
Set the baud rate on port 2 to 2400, on the OCU-DP card in slot 3.
{ocudp-addr}
The {slot:port} address of the OCU-DP card you want to apply the changes to.
{rate}
slot
Slot number (1-8) where the OCU-DP is located
port
Port number or range.
2400
Set OCU-DP baud rate to 2400
4800
Set OCU-DP baud rate to 4800
9600
Set OCU-DP baud rate to 9600
19200
Set OCU-DP baud rate to 19200
38400
Set OCU-DP baud rate to 38400
56000*
Set OCU-DP baud rate to 56000. This is the default.
sw56
Set to switched 56 service
sw56cp
Set to switched 56 service with call progress capability. Sends
special call progress CMI codes to DSU.
64000
Set OCU-DP baud rate to 64000
Содержание Network Device Axxius 800
Страница 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Страница 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Страница 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Страница 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Страница 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Страница 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Страница 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Страница 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Страница 511: ...APPENDIX Loopback Tests In this Appendix n Overview n DS1 Loopbacks n V 35 Loopbacks n V 35 V 54 Loop ...
Страница 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Страница 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...