Axxius 800 - Release 2.2
12-3
Power Supply
Technical Specifications
Technical Specifications
Components
l
24 VDC Power Supply
l
48 VDC NI48 Power Supply
l
48 VDC I48 Power Supply
l
Cable connector
Electrical Input Characteristics
Input power fully isolated from circuit and chassis ground
24 VDC
l
24 (21.0 to 30.0) VDC, +5 ADC, 120 W rated input
l
Startup at 22 V maximum
l
Low voltage shutdown at 19 V minimum
l
High voltage shutdown at 33 V minimum
l
Maximum cold start inrush current: 15 A peak at 30 VDC
48 VDC
l
48 (41.0 to 60.0) VDC, 2.5 ADC, 120 W rated input
l
Startup at 44 V maximum
l
Low voltage shutdown at 37.5 V minimum
l
High voltage shutdown at 66.0 V minimum
l
Maximum cold start inrush current: 7.5 A peak at 60 VDC
Electrical Output Characteristics
l
5 VDC, 20 A maximum
Содержание Network Device Axxius 800
Страница 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Страница 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Страница 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Страница 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Страница 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Страница 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Страница 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Страница 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Страница 511: ...APPENDIX Loopback Tests In this Appendix n Overview n DS1 Loopbacks n V 35 Loopbacks n V 35 V 54 Loop ...
Страница 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Страница 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...