Axxius 800 - Release 2.2
5-71
CLI Commands
set
set alarms
Use the set alarms to manually set an alarm state for testing.
Syntax:
set alarms {critical|major|minor} {off|on}
Example:
set alarms critical on
The example set the alarm state of critical on.
{ciritical|major|minor}
{off|on}
set autoexit
Use the set autoexit to set the autoexit feature.
Syntax:
set autoexit {off|on}
Example:
set autoexit on
The example will enable the auto-exit feature.
{off|on}
critical
Sets a critical alarm
major
Sets a major alarm.
minor
Sets a minor alarm.
off
Disables the alarm state.
on
Enable the alarm state.
off
Turn off the automatic logout option.
on
Enable the automatic exit option. Users will be automatically logged off
after 20 minutes of inactivity.
Содержание Network Device Axxius 800
Страница 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Страница 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Страница 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Страница 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Страница 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Страница 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Страница 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Страница 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Страница 511: ...APPENDIX Loopback Tests In this Appendix n Overview n DS1 Loopbacks n V 35 Loopbacks n V 35 V 54 Loop ...
Страница 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Страница 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...