iv
Axxius 800 - Release 2.2
Preface
Compliance
The Facility Interface Code (FIC) associated with each private line application represents the type of
service that will be provided by the telephone company. The following are currently registered:
An FCC-compliant telephone and modular plug is provided with this equipment. This equipment is
designed to be connected to the telephone network or premises wiring using a compatible modular jack
which is Part 68 Compliant. See installation instructions for details.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required. But if advance notice is not practical, the
telephone company will notify the customer as soon as possible. Also, you will be advised of your right to
file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment operations, or procedures that could
affect the operation of the equipment. If this happens, the telephone company will provide advance notice
so that you may make necessary modifications in order to maintain uninterrupted service.
If trouble is experienced with the Axxius 800, please contact the Carrier Access Customer Support at (800)
786-9929 or (303) 442-5455. If the equipment is causing harm to the network, the telephone company may
request you to remove the equipment from the network until the problem is resolved.
No repairs are to be made by you. Repairs are to be made only by Carrier Access or its licensees.
Unauthorized repairs void registration and warranty.
This equipment cannot be used on public coin service provided by the telephone company. Connection to
Party Line Service is subject to state tariffs. (Contact your state public utility commission, public service
commission or corporation commission for information.3
Port:
FIC:
SOC:
Jack:
HD Quad T1 1.544 Mbps
04DU9-BN
6.0F
RJ48C
HD Quad T1 1.544 Mbps
04DU9-DN
6.0F
RJ48C
HD Quad T1 1.544 Mbps
04DU9-1KN
6.0F
RJ48C
HD Quad T1 1.544 Mbps
04DU9-1SN
6.0F
RJ48C
HD Quad DS1 ADPCM 1.544 Mbps
04DU9-BN
6.0F
RJ48C
HD Quad DS1 ADPCM 1.544 Mbps
04DU9-DN
6.0F
RJ48C
HD Quad DS1 ADPCM 1.544 Mbps
04DU9-1KN
6.0F
RJ48C
HD Quad DS1 ADPCM 1.544 Mbps
04DU9-1SN
6.0F
RJ48C
Front Interface T1 1.544 Mbps
04DU9-BN
6.0F
RJ48C
Front Interface T1 1.544 Mbps
04DU9-DN
6.0F
RJ48C
Front Interface T1 1.544 Mbps
04DU9-1KN
6.0F
RJ48C
Front Interface T1 1.544 Mbps
04DU9-1SN
6.0F
RJ48C
V.34 Modem Interface
02LS2
9.0F
RJ11C
Содержание Network Device Axxius 800
Страница 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Страница 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Страница 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Страница 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Страница 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Страница 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Страница 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Страница 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Страница 511: ...APPENDIX Loopback Tests In this Appendix n Overview n DS1 Loopbacks n V 35 Loopbacks n V 35 V 54 Loop ...
Страница 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Страница 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...