![CARLO GAVAZZI VariFlex3 RVFFA3400400F Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/carlo-gavazzi/variflex3-rvffa3400400f/variflex3-rvffa3400400f_quick-start-manual_2558654059.webp)
Motor Controllers AC Variable Frequency Drives
Type Variflex
3
RVFF
Specifications are subjected to change without notice.
58
Group 17 IM Motor Automatic Tuning Parameters
Code
Parameter Name
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
17-00
Mode selection of automatic
tuning
0: Rotation Auto-tune
VF: 2
SLV: 6
-
O
O
X
1: Static Auto-tune
2: Stator resistance measurement
3: Reserved
4: Loop test
5: Rotation (loop test + autotune)
6. Static (loop test + autotune)
17-01 Motor rated output power
0.00~600.00
-
KW
O
O
X
17-02 Motor rated current
0.1~999.9
-
A
O
O
X
17-03 Motor rated voltage
0.0~510.0
440
V
O
O
X
17-04 Motor rated frequency
4.8~400.0
50.0 /
60.0
Hz
O
O
X
17-05 Motor rated speed
0~24000
KVA
*a
rpm
O
O
X
17-06 Pole number of motor
2~16 (Even)
4
Pole
O
O
X
17-07
Reserved
17-08 Motor no-load voltage
400V: 100~480
KVA
*a
V
O
O
X
17-09 Motor excitation current
0.01~600.00
(15%~70% motor rated current)
KVA
*a
A
O
O
X
■
1
17-10 Automatic tuning start
0: Disable
0
-
O
O
X
1: Enable
17-11
Error history of automatic
tuning
0: No error
0
-
O
O
X
1: Motor data error
2. Stator resistance tuning error
3. Leakage induction tuning error
4. Rotor resistance tuning error
5. Mutual induction tuning error
6. DT error
7. Encoder error
8. Motor
’s acceleration error
9. Warning
17-12
Motor leakage inductance
scale
0.1~15.0
3.4
%
X
O
X
17-13 Motor slip frequency
0.10~20.00
1.00
Hz
X
O
X
17-14 Rotational selection 1
0: VF
O
-
O
O
X
1: SLV
*a: KVA means the default value of this parameter will be changed by different capacities of inverter.
■
1: It can be set when 17-00=1, 2, 6.