![CARLO GAVAZZI VariFlex3 RVFFA3400400F Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/carlo-gavazzi/variflex3-rvffa3400400f/variflex3-rvffa3400400f_quick-start-manual_2558654014.webp)
Motor Controllers AC Variable Frequency Drives
Type Variflex
3
RVFF
Specifications are subjected to change without notice.
13
3.3.2 General Specifications
*1: Speed control accuracy will be different from the installation conditions and motor types.
*2: The factory default carrier frequency is different from models.
C
o
n
tr
o
l
C
h
ar
a
cte
ri
sti
c
s
Operation Modes
LED keypad with seven-segment display
Control Modes
V/F, SLV, PMSLV with space vector PWM mode
Frequency Control Range
0.1Hz
~
400.0Hz
Frequency Accuracy
(Temperature change)
Digital references: ±0.01
%
(-10 to +40
℃
), analog references: ±0.1
%
(25
℃
±10
℃
)
Speed Control Accuracy
±0.5
%
(Sensorless Vector Control Mode)
*1
Frequency Setting
Resolution
Digital references: 0.01Hz, analog references: 0.06Hz/60Hz
Output Frequency
Resolution
0.01Hz
Inverter Overload
120%/1 min
Frequency Setting Signal
DC 0
~
+10V / 0~20mA or 4
~
20mA
Acceleration/ Deceleration
Time
0.0
~
6000.0 seconds (separately set acceleration and deceleration time)
Voltage, Frequency
Characteristics
Custom V/F curve based on parameters
Braking Torque
About 20%
Main Control Functions
Auto tuning, soft-PWM, over voltage protection, dynamic braking, speed search, restart upon momentary power
loss, 2 sets of PID control, slip compensation, RS-485 communication standard, simple PLC function, 2 sets of
analog outputs, safety switch
Other Functions
Accumulated power-on/ run time, 4 sets of fault history records and latest fault record state, energy-saving
function setting, phase loss protection, smart braking, DC braking, dwell
,
S curve acceleration and
deceleration, Up/Down operation, Modbus, BACnet MS/TP and Metasys N2 communication protocol, display
of multi-engineering unit, Local/ Remote switch, SINK/SOURCE input interface selection, user parameter
settings
Pr
o
te
cti
o
n
F
u
n
cti
o
n
Stall Prevention
Current level can be setting (It can be set separately in acceleration or constant speed; it can be set with or
without protection in deceleration)
Instantaneous Over Current
(OC) and Output Short-
Circuit (SC) Protection
Inverter stops when the output current exceeds 160% of the inverter rated current
Inverter Overload Protection
(OL2)
If inverter rated current 120%/1min is exceeded, inverter stops. The factory default carrier frequency is
2~4KHZ
*2
Motor Overload Protection
(OL1)
Electrical overload protection curve
Over voltage (OV)
Protection
If the main circuit DC voltage rises over 820V, the motor stops running.
Under voltage (UV)
Protection
If the main circuit DC voltage falls below 380V, the motor stops running.
Auto-Restart after
Momentary Power Loss
Power loss exceeds 15ms.
Auto-restart function available after momentary power loss in 2 sec.
Overheat(OH) Protection
Use temperature sensor for protection.
Ground Fault (GF)
Protection
Use current sensor for protection.
DC Bus Charge Indicator
When main circuit DC voltage ≥ 50V, the CHARGE LED turns on.
Output Phase Loss (OPL)
Protection
If the OPL is detected, the motor stops automatically.
En
vi
ro
n
m
e
n
t
Sp
e
ci
fi
ca
ti
o
n
s
Installation Location
Indoor (protected from corrosive gases and dust)
Ambient Temperature
-10
℃
to +40
℃
(14
℉
to 104
℉
) without de-rating; with de-rating, its maximum operation temperature is 60
℃
(140
℉
).
Storage Temperature
-20
℃
to +70
℃
(-4
℉
to +158
℉
)
Humidity
95
%
RH or less (no condensation)
Altitude and Vibration
Altitude of 1000m (3181ft) or below, below 5.9m/s
2
(0.6G)
Communication Function
Built-in RS-485 as standard (Modbus protocol with RJ45/BACnet/ Metasys N2)
PLC Function
Built-in
EMI Protection
The built-in noise filter complies with EN61800-3 available for inverters 400V 75HP or below
EMS Protection
in compliance with EN61800-3
Safety
Certification
CE Declaration
in compliance with EN61800-3 (CE & RE) and EN61800-5-1 (LVD, Low-Voltage Directive)
UL Certification
UL508C
Accessories
1 to 8 Pump card, Profibus card
Содержание VariFlex3 RVFFA3400400F
Страница 1: ...Quick Start Guide Motor Controllers AC Variable Frequency Drives Type VariFlex3 RVFF...