Motor Controllers AC Variable Frequency Drives
Type Variflex
3
RVFF
Specifications are subjected to change without notice.
14
3.4 General Wiring Diagram
The following is the standard wiring diagram for the RVFF inverter (
◎
indicates main circuit terminals
and
○
indicates control circuit terminals). Locations and symbols of the wiring terminal block might
be different due to different models of RVFF.
MC
NFB
B1/P
B2
R/L1
S/L2
S1
S2
S6
S5
S4
S3
Analog output 1
24V
24VG
Source(PNP)
SW3
AO1
AO2
GND
E
CN3
Analog output 2
E
T/L3
U/T1
V/T2
W/T3
CN6
(RJ45)
1
2
GND
Common terminal of analog signal
E
+10V
AI1
(0~10V, 20K
Ω)
AI2
P
P
S(+)
S(-)
PI
PO
MT
PTC Motor temperature detector input
P
P
IM
R2C
R1A
R1B
R1C
R2A
F1
F2
(0~10V/0~20mA or 4~20mA, 250
Ω)
V
SW2
0V
Grounding resistance
should lower than 100
Ω
Analog signal output 1, 2
(DC 0~10V)/4-20mA
Option Card (JN5-IO-8DO)
Multi-function relay output
250VAC, under to 1A
30VDC, under to 1A
Energy meter pulse output
GND
RS485
*2
*1
*3
*4
R3C
R3A
SW1
SW6
V
V
I
I
AO1
AO2
SW5
OFF
ON
Braking resistor
F
a
s
t
a
c
ti
n
g
f
u
s
e
Main circuit power
Forward rotation/stop
Reverse rotation/stop
UP command
DOWN command
Multi-step speed
command 1
Fault reset
0~10V
0~10V/0~20mA or
4~20mA
E
x
te
rn
a
l
a
n
a
lo
g
i
n
p
u
t
Pulse input
Screened
Cable
Screened Cable,
Twisted Pair
P
Terminal symbol
Indicates main circuit
Indicates control circuit
M
u
lt
i-
fu
n
c
ti
o
n
i
n
p
u
t
Sink(NPN), Default setting
Power terminal of digital signal (PNP)
Common terminal of digital signal (NPN)
Connection terminal of shielding wire
Power for analog input, +10V, 20mA
Multi-function analog input
Multi-function analog input
Pulse command input 32K Hz. Max.
Run Permissive input
I
Default setting
Remark:
*1: Models IP20 200V 5~30HP, 400V 5~40HP and IP55 400V 5~25HP have a built-in braking transistor so that the braking resistor can be connected between
terminal B1 and B2.
*2: The multi-function digital input terminals S1~S6 can be set to Source (PNP) or Sink (NPN) mode via SW3.
*3: The multi-function analog input 2 (AI2) can be set to the voltage command input (0~10v) or the current command input (4~20mA) via SW2.
*4: Run permissive input F1 & F2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input, open the link
between F1 and F2.
1: Data+
2: Data-
3: Data+
4: Reserved
5: Reserved
6: Data-
7: 5V
8: GND
Remark:
*1: Model 400V 5-40HP has a built-in braking transistor so that the braking resistor can be connected between terminal B1 and B2.
*2: The multi-function digital input terminals S1-S6 can be set to Source (PNP) or Sink (NPN) mode via SW3.
*3: The multi-function analog input 2 (AI2) can be set to the voltage command input (0-10V) or the current command input (4-20mA) via SW2.
*4: Run permissive input F1 & F2 is a normally closed input. This input should be closed to enable the inverter output. To active this input, open the link
between F1 and F2.