Group 12 Monitoring Parameters
Code
Parameter Name
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
12-59 DI/DO status of previous fault
Display DI/DO status of previous
fault description is similar to 12-05
-
-
O
O
O
12-60
Inverter status of previous
fault
Display inverter status of previous
fault description is similar to 12-43
-
-
O
O
O
12-61 Trip time 1 of last fault
Display the operation time of last
time’s fault, 12-62 is the days,
while 12-61 is the ephemeral hours
-
Hr
O
O
O
12-62 Trip time 2 of last fault
-
day
O
O
O
12-63 Recent warning messages
Display the recent warning
messages
-
-
O
O
O
12-64 Previous warning message
Display the previous warning
message
-
-
O
O
O
12-65
~
12-66
Reserved
12-67 Cumulative energy
0.0~999.9
0
kWH
r
O
O
O
12-68 Cumulative energy
0~60000
0
MW
Hr
O
O
O
12-69 Cumulative electricity price
0~9999
0.0
$
O
O
O
12-70 Cumulative electricity price
0~60000
0
$
O
O
O
12-71 Flow meter feedback
1~50000
0
GP
M
O
O
O
12-72
Reserved
12-73
Reserved
12-74 PSI Target
0.01~25.50
02.00 PSI
O
X
X
12-75 PSI Feedback
0.01 25.50
0.00 PSI
O
X
X
12-76 No-Load voltage
0.0~600.0
1.0
V
X
O
X
12-77 HVAC setpoint
1~50000
5000
GP
M
O
O
O
12-78
Reserved
12-79 Pulse input percentage
0.0~100.0
0.0
%
O
O
O
12-82 Motor Load
0 ~ 200.0
-
%
O
O
O
*7
* Models of inverter ratings above 400V 75HP (including 75HP) do not support functions of heatsink
temperature display.
* Maximum upper limit in motor speed (rpm) of parameter 12-22 is 65535.
Group 13 Maintenance Function Group
Code
Parameter Name
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
13-00 Inverter capacity selection
00H~FFH
-
-
O
O
O
*4
13-01 Software version
0.0-9.99
-
-
O
O
O
*4
13-02
Clears cumulative operation
hours function
0: Disable
0
-
O
O
O
*1
1: Enable (Clear)
13-03 Cumulative operation hours 1 0~23
-
hr
O
O
O
*4
13-04 Cumulative operation hours 2 0~65534
-
day
O
O
O
*4
13-05
Selection of cumulative
operation time
0: Accumulative time in power on
0
-
1: Accumulative time in operation