35
Group 05 Multi-Speed Function Group
Code
Parameter Name
Setting Range
Default Unit Control Mode Attribute
V/F SLV PM
SLV
05-00 Acceleration and deceleration
selection of Multi-Speed
0: Acceleration and deceleration
time are set by 1~4
0
-
O
O
O
1: Acceleration and deceleration
time setting respectively
05-01 Frequency setting of Speed-
Stage 0
0.00~400.00
5.00
Hz
O
O
O
*1
05-02 Frequency setting of Speed-
Stage 1
0.00~400.00
5.00
Hz
O
O
O
05-03 Frequency setting of Speed-
Stage 2
0.00~400.00
10.00
Hz
O
O
O
05-04 Frequency setting of Speed-
Stage 3
0.00~400.00
20.00
Hz
O
O
O
05-05 Frequency setting of Speed-
Stage 4
0.00~400.00
30.00
Hz
O
O
O
05-06 Frequency setting of Speed-
Stage 5
0.00~400.00
40.00
Hz
O
O
O
05-07 Frequency setting of Speed-
Stage 6
0.00~400.00
50.00
Hz
O
O
O
05-08 Frequency setting of Speed-
Stage 7
0.00~400.00
50.00
Hz
O
O
O
05-09 Frequency setting of Speed-
Stage 8
0.00~400.00
5.00
Hz
O
O
O
05-10 Frequency setting of Speed-
Stage 9
0.00~400.00
5.00
Hz
O
O
O
05-11 Frequency setting of Speed-
Stage 10
0.00~400.00
5.00
Hz
O
O
O
05-12 Frequency setting of Speed-
Stage 11
0.00~400.00
5.00
Hz
O
O
O
05-13 Frequency setting of Speed-
Stage 12
0.00~400.00
5.00
Hz
O
O
O
05-14 Frequency setting of Speed-
Stage 13
0.00~400.00
5.00
Hz
O
O
O
05-15 Frequency setting of Speed-
Stage 14
0.00~400.00
5.00
Hz
O
O
O
05-16 Frequency setting of Speed-
Stage 15
0.00~400.00
5.00
Hz
O
O
O
05-17 Acceleration time setting of
multi speed 0
0.1~6000.0
10.0
s
O
O
O
05-18 Deceleration time setting of
multi Speed 0
0.1~6000.0
10.0
s
O
O
O
05-19 Acceleration time setting of
multi speed 1
0.1~6000.0
10.0
s
O
O
O
05-20 Deceleration time setting of
multi speed 1
0.1~6000.0
10.0
s
O
O
O
05-21 Acceleration time setting of
multi speed 2
0.1~6000.0
10.0
s
O
O
O
Содержание VariFlex3 RVFFA3400400F