37
Group 05 Multi-Speed Function Group
Code
Parameter Name
Setting Range
Default Unit Control Mode Attribute
V/F SLV PM
SLV
05-45 Acceleration time setting of
Multi speed 14
0.1~6000.0
10.0
s
O
O
O
05-46 Deceleration time setting of
multi speed 14
0.1~6000.0
10.0
s
O
O
O
05-47 Acceleration time setting of
multi speed 15
0.1~6000.0
10.0
s
O
O
O
05-48 Deceleration time setting of
multi speed 15
0.1~6000.0
10.0
s
O
O
O
Group 06
Automatic Program Operation Parameters
Code
Parameter Name
Setting Range
Default Unit Control Mode Attribute
V/F SLV PM
SLV
06-00
Automatic operation mode
selection
0: Disable
0
-
O
O
X
1: Single cycle operation. Restart
based on the previous stopped
speed.
2: Continuous cycle operation.
Restart based on the previous
stopped speed.
3: The on-going operation based
on the speed of the last stage.
Restart based on the previous
stopped speed.
4: Single cycle operation. Restart
based on the speed of stage 1.
5: Continuous cycle operation
mode. Restart based on the
speed of stage 1.
6: The on-going operation based
on the speed of the last stage.
Restart based on the speed of
stage 1.
06-01
Run freq. setting of speed-
stage 1
0.00~400.00
5.00
Hz
O
O
O
*1
06-02
Run freq. setting of speed-
stage 2
0.00~400.00
10.00
Hz
O
O
O
*1
06-03
Run freq. setting of speed-
stage 3
0.00~400.00
20.00
Hz
O
O
O
*1
06-04
Run freq. setting of speed-
stage 4
0.00~400.00
30.00
Hz
O
O
O
*1
06-05
Run freq. setting of speed-
stage 5
0.00~400.00
40.00
Hz
O
O
O
*1
06-06
Run freq. setting of speed-
stage 6
0.00~400.00
50.00
Hz