Chapter 17
17-154
MAIL-OF
1
Title
Switch for prohibiting transmission to email destinations
Purpose of use, When used
Prohibit transmission to email destinations by prohibiting the input of email addresses from the
address book.
Precautions for use
Email addresses which are already registered must be deleted manually since it is still possible to use
them even when '1' is set for this item.
Settings and adjustment
ranges
0: Transmission to email destinations is not prohibited.
1: Transmission to email destinations is prohibited.
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
IFAX-OF
1
Title
Switch for prohibiting transmission to i-FAX destinations
Purpose of use, When used
Prohibit transmission of i-FAX destinations by prohibiting the input of i-FAX addresses from the
address book.
Precautions for use
i-FAX addresses which are already registered must be deleted manually since it is still possible to use
them even when '1' is set for this item.
Settings and adjustment
ranges
0: Transmission to i-FAX destinations is not prohibited.
1: Transmission to i-FAX destinations is prohibited.
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
LDAP-DEF
1
Title
Default value selector switch for LDAP server search conditions
Purpose of use, When used
Change the default conditions of the search target attributes which are specified when conducting
advanced LDAP server searches.
Precautions for use
-
Settings and adjustment
ranges
0: 'Name'
1: 'Email'
2: 'Fax'
3: 'Organization'
4: 'Organization unit'
5: 'To be registered 1' (set as desired by the user)
6: 'To be registered 2' (set as desired by the user)
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
COPIER > OPTION > USER > LDAP-SW
Additional description and
notes
-
FREE-DSP
2
Title
Switching of charge invalidation display
Purpose of use, When used
When there is no hard switch used to select whether to perform charging at the vender's side, it needs
to be controlled by a soft switch. In such a case, this item is used to select whether to display the charge
invalidation screen (soft switch).
Precautions for use
-
Settings and adjustment
ranges
0: The charge invalidation screen is not displayed.
1: The charge invalidation screen is displayed.
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
-
Related service modes
-
Additional description and
notes
-
COPIER > OPTION > USER
Item
Level
Description
Содержание iR3245
Страница 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Страница 2: ......
Страница 6: ......
Страница 25: ...Chapter 1 Introduction...
Страница 26: ......
Страница 28: ......
Страница 64: ......
Страница 65: ...Chapter 2 Installation...
Страница 66: ......
Страница 120: ......
Страница 121: ...Chapter 3 Basic Operation...
Страница 122: ......
Страница 124: ......
Страница 128: ......
Страница 129: ...Chapter 4 Main Controller...
Страница 130: ......
Страница 132: ......
Страница 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Страница 152: ......
Страница 153: ...Chapter 5 Original Exposure System...
Страница 154: ......
Страница 184: ......
Страница 185: ...Chapter 6 Laser Exposure...
Страница 186: ......
Страница 188: ......
Страница 197: ...Chapter 7 Image Formation...
Страница 198: ......
Страница 227: ...Chapter 8 Pickup Feeding System...
Страница 228: ......
Страница 232: ......
Страница 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Страница 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Страница 278: ......
Страница 279: ...Chapter 9 Fixing System...
Страница 280: ......
Страница 282: ......
Страница 297: ...Chapter 10 External and Controls...
Страница 298: ......
Страница 302: ......
Страница 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Страница 342: ......
Страница 343: ...Chapter 11 MEAP...
Страница 344: ......
Страница 346: ......
Страница 397: ...Chapter 12 e maintenance imageWARE Remote...
Страница 398: ......
Страница 400: ......
Страница 408: ......
Страница 409: ...Chapter 13 Maintenance and Inspection...
Страница 410: ......
Страница 412: ......
Страница 424: ...Chapter 13 13 12...
Страница 425: ...Chapter 14 Standards and Adjustments...
Страница 426: ......
Страница 428: ......
Страница 433: ...Chapter 14 14 5 Execute the following in Service Mode ADF white level adjustment COPIER FUNCTION CCD DF WLVL1 2 3 4...
Страница 436: ......
Страница 437: ...Chapter 15 Correcting Faulty Images...
Страница 438: ......
Страница 440: ......
Страница 465: ...Chapter 16 Self Diagnosis...
Страница 466: ......
Страница 468: ......
Страница 493: ...Chapter 17 Service Mode...
Страница 494: ......
Страница 498: ......
Страница 690: ......
Страница 691: ...Chapter 18 Upgrading...
Страница 692: ......
Страница 694: ......
Страница 738: ...Chapter 18 18 44...
Страница 739: ...Chapter 19 Service Tools...
Страница 740: ......
Страница 741: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Oils and Solvents 19 1...
Страница 742: ......
Страница 744: ......
Страница 745: ...Jul 3 2008...
Страница 746: ......