Chapter 16
16-3
16.1.2 E202 to E248, E280 (Reader)
0019-7880
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-16-2
16.1.3 E261 to E315 (DC Controller, Main Controller)
0019-7874
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-16-3
Code Cause/Detection
Details
Measures
E202
There is an error in the detection of the CCD home position.
0001 The attempt to detect the home position fails when the CCD is
moved forward.
Disconnect and then connect the harness connector. Replace the optical HP sensor,
optical motor, and reader controller PCB.
0002 The attempt to detect the home position fails when the CCD is
moved back.
Disconnect and then connect the harness connector. Replace the optical HP sensor,
optical motor, and reader controller PCB.
E225
The light intensity of the CCD is faulty.
Disconnect and then connect the flexible cable. Replace the flexible cable, CCD unit,
and reader controller PCB.
E227
The reader unit power supply (24V) is faulty.
0001 At time of power-on, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0002 At the start of a job, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0003 At the end of a job, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
0004 When a load is being driven, the 24V port is off.
Disconnect and then connect the power supply harness connector. Replace the power
supply.
E248
EEPROM error
0001 An error has occurred at power-on.
Replace the reader controller PCB.
0002 An error has occurred during write operation.
Replace the reader controller PCB.
0003 An error has occurred during read operation following write
operation.
Replace the reader controller PCB.
E280
Reading unit communication error
0001 Reception status error
Disconnect and then connect the flexible cable. Replace the flexible cable
0002 Reception interrupt error
Disconnect and then connect the flexible cable. Replace the flexible cable
0003 Insufficient insertion of the reading unit connector
Disconnect and then connect the flexible cable. Replace the flexible cable
Code
Cause
Remedy
E261
The zero-cross signal is faulty.
0000
When the relay is on, the zero-cross signal is not detected for 500 msec
or more.
Replace the AC driver PCB. Replace the DC controller PCB.
E315
There is an error in image data.
0007 There is an error in JBIG encoding.
Turn off and then back on the power.
000d There is an error in JBIG decoding.
Turn off and then back on the power.
000e Error in decoding of software
Replace the main controller PCB
0025 Error in ROTU hardware
Replace SDRAM. Replace HDD. Replace the main controller PCB.
0027 Error in ROTU timeout
Replace SDRAM. Replace HDD. Replace the main controller PCB.
0033 Error in MemFill hardware
Replace the main controller PCB.
0035 Error in MemFill timeout
Replace the main controller PCB.
0100 Error in PrcOverRun
Replace the main controller PCB.
0500 Error in device timeout
[location to be detected] image process module (SCIO)
[Detection timing] when there is no interruption 2 min after the
operation has been started
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0501 Device: abnormal termination error
[location to be detected] image process module (SCIO)
[Detection timing] When abnormal interruption is detected after the
operation has been started.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0510 Device: timeout error
[Location to be detected] image process module (SCIP)
[Detection timing] when there is no interruption 2 min after the
operation has been started.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0511 Device: abnormal termination error
[Location to be detected] image process module (SCIP)
[Detection timing] when abnormal interruption is detected after the
operation has been detected.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0520 Device: timeout error
[Location to be detected] image process module (CMIP)
[Detection timing] When there is no interruption 2 min after the
operation has been started
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
0521 Device: abnormal termination error
[Location to be detected] image process module (CMIP)
[Detection timing] when abnormal interruption is detected after the
operation has been detected.
Check connection with DDI-S cable(RCON). Replace the main
controller PCB.
Содержание iR3245
Страница 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Страница 2: ......
Страница 6: ......
Страница 25: ...Chapter 1 Introduction...
Страница 26: ......
Страница 28: ......
Страница 64: ......
Страница 65: ...Chapter 2 Installation...
Страница 66: ......
Страница 120: ......
Страница 121: ...Chapter 3 Basic Operation...
Страница 122: ......
Страница 124: ......
Страница 128: ......
Страница 129: ...Chapter 4 Main Controller...
Страница 130: ......
Страница 132: ......
Страница 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Страница 152: ......
Страница 153: ...Chapter 5 Original Exposure System...
Страница 154: ......
Страница 184: ......
Страница 185: ...Chapter 6 Laser Exposure...
Страница 186: ......
Страница 188: ......
Страница 197: ...Chapter 7 Image Formation...
Страница 198: ......
Страница 227: ...Chapter 8 Pickup Feeding System...
Страница 228: ......
Страница 232: ......
Страница 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Страница 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Страница 278: ......
Страница 279: ...Chapter 9 Fixing System...
Страница 280: ......
Страница 282: ......
Страница 297: ...Chapter 10 External and Controls...
Страница 298: ......
Страница 302: ......
Страница 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Страница 342: ......
Страница 343: ...Chapter 11 MEAP...
Страница 344: ......
Страница 346: ......
Страница 397: ...Chapter 12 e maintenance imageWARE Remote...
Страница 398: ......
Страница 400: ......
Страница 408: ......
Страница 409: ...Chapter 13 Maintenance and Inspection...
Страница 410: ......
Страница 412: ......
Страница 424: ...Chapter 13 13 12...
Страница 425: ...Chapter 14 Standards and Adjustments...
Страница 426: ......
Страница 428: ......
Страница 433: ...Chapter 14 14 5 Execute the following in Service Mode ADF white level adjustment COPIER FUNCTION CCD DF WLVL1 2 3 4...
Страница 436: ......
Страница 437: ...Chapter 15 Correcting Faulty Images...
Страница 438: ......
Страница 440: ......
Страница 465: ...Chapter 16 Self Diagnosis...
Страница 466: ......
Страница 468: ......
Страница 493: ...Chapter 17 Service Mode...
Страница 494: ......
Страница 498: ......
Страница 690: ......
Страница 691: ...Chapter 18 Upgrading...
Страница 692: ......
Страница 694: ......
Страница 738: ...Chapter 18 18 44...
Страница 739: ...Chapter 19 Service Tools...
Страница 740: ......
Страница 741: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Oils and Solvents 19 1...
Страница 742: ......
Страница 744: ......
Страница 745: ...Jul 3 2008...
Страница 746: ......