Chapter 5
5-12
5.3.4 Detecting the Size of Originals
5.3.4.1 Overview
0019-4675
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
The machine identifies the original size by the combination of measurement result of reflection light from the reflection sensor and specific points of CCD. Also to
identify it accurately even though an original moves when ADF is closed, the machine measures 2 points for each size.
- Main scanning direction: CCD (AB type: 8 points measurement, inch type: 6 points measurement)
- Sub scanning direction: Reflection type photo sensor (AB type: 1 point, inch type: 1 point (original sensor 2 is not used.))
The followings are the procedures of original size identification.
1)External light search (main scanning direction only)
According to the LED status, the machine identifies the CCD level of each detection position in main scanning direction.
2)Output level detection of each sensor
The machine turns on the LED on CCD unit and measures the CCD level of each detection position in main scanning direction.
Also, turns on the LED on reflection type photo sensor in sub scanning direction and measures the sensor output.
The original size is identified by the combination of these output result.
5.3.4.2 Control Details
0019-4676
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
For main scanning direction, the machine moves the CCD unit to the following CCD original detection positions according to the location of original to measure
the CCD level of each detection position. For sub scanning direction, the machine uses the original sensor 0, 1 to identify sizes.
F-5-12
1. 2 points original detection at each detection position
For each point of measurement in main scanning direction, the machine checks the presence/absence of an original with reference to the CCD output at 2 points
near the point of measurement.
* The machine checks if the signal is changed or not from ADF (pressure plate) open to close at both points of 1A and 1B.
Change in the signal: Yes
Change in the signal: No
Judgment is done by the measurement results of 1A and 1B, and it indicates the presence of original if either point shows absence (absence). It indicates absence
of original if both signals show Yes (presence).
F-5-13
T-5-3
Change
Result of detection
1A
1B
Yes
Yes
Original absence
No
Yes
Original presence
Yes
No
Original presence
No
No
Original presence
Original sensor 0
Original detection
position 1
B5
B6
A5
A4
B5R
A4R
B4
A3
CCD original detection position
LTRR
STMT
LTR
LGL
279.4×431.8mm
(11"×17")
AB type
Inch type
STMTR
Original detection
position 2
Original detection
position 3
Original detection
position 4
CCD original detection position
Original detection
position 1
Original detection
position 2
Original detection
position 3
Original sensor 1
approx 4mm
approx 13mm
1A=additional
detection point 1
Borderline of
original size
1B=conventional
detection point 2
Borderline of
original size
Содержание iR3245
Страница 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Страница 2: ......
Страница 6: ......
Страница 25: ...Chapter 1 Introduction...
Страница 26: ......
Страница 28: ......
Страница 64: ......
Страница 65: ...Chapter 2 Installation...
Страница 66: ......
Страница 120: ......
Страница 121: ...Chapter 3 Basic Operation...
Страница 122: ......
Страница 124: ......
Страница 128: ......
Страница 129: ...Chapter 4 Main Controller...
Страница 130: ......
Страница 132: ......
Страница 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Страница 152: ......
Страница 153: ...Chapter 5 Original Exposure System...
Страница 154: ......
Страница 184: ......
Страница 185: ...Chapter 6 Laser Exposure...
Страница 186: ......
Страница 188: ......
Страница 197: ...Chapter 7 Image Formation...
Страница 198: ......
Страница 227: ...Chapter 8 Pickup Feeding System...
Страница 228: ......
Страница 232: ......
Страница 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Страница 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Страница 278: ......
Страница 279: ...Chapter 9 Fixing System...
Страница 280: ......
Страница 282: ......
Страница 297: ...Chapter 10 External and Controls...
Страница 298: ......
Страница 302: ......
Страница 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Страница 342: ......
Страница 343: ...Chapter 11 MEAP...
Страница 344: ......
Страница 346: ......
Страница 397: ...Chapter 12 e maintenance imageWARE Remote...
Страница 398: ......
Страница 400: ......
Страница 408: ......
Страница 409: ...Chapter 13 Maintenance and Inspection...
Страница 410: ......
Страница 412: ......
Страница 424: ...Chapter 13 13 12...
Страница 425: ...Chapter 14 Standards and Adjustments...
Страница 426: ......
Страница 428: ......
Страница 433: ...Chapter 14 14 5 Execute the following in Service Mode ADF white level adjustment COPIER FUNCTION CCD DF WLVL1 2 3 4...
Страница 436: ......
Страница 437: ...Chapter 15 Correcting Faulty Images...
Страница 438: ......
Страница 440: ......
Страница 465: ...Chapter 16 Self Diagnosis...
Страница 466: ......
Страница 468: ......
Страница 493: ...Chapter 17 Service Mode...
Страница 494: ......
Страница 498: ......
Страница 690: ......
Страница 691: ...Chapter 18 Upgrading...
Страница 692: ......
Страница 694: ......
Страница 738: ...Chapter 18 18 44...
Страница 739: ...Chapter 19 Service Tools...
Страница 740: ......
Страница 741: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Oils and Solvents 19 1...
Страница 742: ......
Страница 744: ......
Страница 745: ...Jul 3 2008...
Страница 746: ......