Chapter 17
17-118
17.6.1.9 COPIER > OPTION > BODY (9/15)
0019-9608
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-17-58
COPIER > OPTION > BODY
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
Description
DA-PORT
2
Title
Port setting when DA is installed
Purpose of use, When used
This item is used when DA is installed. (used in Japanese machines only, not used in overseas
machines) Set the port for communication with the DA (Digital Accessory).
Precautions for use
When this item is set to '1', the following items are also set to ON.
COPIER > OPTION > BODY > STS-PORT
> CMD-PORT
> SSH-SW
> DA-PORT
Settings and adjustment
ranges
0: Closed
1: Opened (when DA is installed)
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
For future expansion (The setting must not be changed.)
Related service modes
-
Additional description and
notes
-
DA-CNCT
2
Title
WPGW connection setting
Purpose of use, When used
Set the WPGW connection. (used in Japanese machines only, not used in overseas machines)
Precautions for use
-
Settings and adjustment
ranges
0: OFF
1: ON
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
WPGW : Workplace Gateway
CHNG-STS
2
Title
Setting of T.O.T. status connection port number
Purpose of use, When used
This item is used when Service NAVI is used. Set the number of the port used for the status connection
in T.O.T.
Precautions for use
-
Settings and adjustment
ranges
1 to 65535
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
20010
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
CHNG-CMD
2
Title
Setting of T.O.T. command connection port number
Purpose of use, When used
This item is used when Service NAVI is used. Set the number of the port number for the command
connection in T.O.T.
Precautions for use
-
Settings and adjustment
ranges
1 to 65535
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
20000
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
Содержание iR3245
Страница 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Страница 2: ......
Страница 6: ......
Страница 25: ...Chapter 1 Introduction...
Страница 26: ......
Страница 28: ......
Страница 64: ......
Страница 65: ...Chapter 2 Installation...
Страница 66: ......
Страница 120: ......
Страница 121: ...Chapter 3 Basic Operation...
Страница 122: ......
Страница 124: ......
Страница 128: ......
Страница 129: ...Chapter 4 Main Controller...
Страница 130: ......
Страница 132: ......
Страница 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Страница 152: ......
Страница 153: ...Chapter 5 Original Exposure System...
Страница 154: ......
Страница 184: ......
Страница 185: ...Chapter 6 Laser Exposure...
Страница 186: ......
Страница 188: ......
Страница 197: ...Chapter 7 Image Formation...
Страница 198: ......
Страница 227: ...Chapter 8 Pickup Feeding System...
Страница 228: ......
Страница 232: ......
Страница 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Страница 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Страница 278: ......
Страница 279: ...Chapter 9 Fixing System...
Страница 280: ......
Страница 282: ......
Страница 297: ...Chapter 10 External and Controls...
Страница 298: ......
Страница 302: ......
Страница 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Страница 342: ......
Страница 343: ...Chapter 11 MEAP...
Страница 344: ......
Страница 346: ......
Страница 397: ...Chapter 12 e maintenance imageWARE Remote...
Страница 398: ......
Страница 400: ......
Страница 408: ......
Страница 409: ...Chapter 13 Maintenance and Inspection...
Страница 410: ......
Страница 412: ......
Страница 424: ...Chapter 13 13 12...
Страница 425: ...Chapter 14 Standards and Adjustments...
Страница 426: ......
Страница 428: ......
Страница 433: ...Chapter 14 14 5 Execute the following in Service Mode ADF white level adjustment COPIER FUNCTION CCD DF WLVL1 2 3 4...
Страница 436: ......
Страница 437: ...Chapter 15 Correcting Faulty Images...
Страница 438: ......
Страница 440: ......
Страница 465: ...Chapter 16 Self Diagnosis...
Страница 466: ......
Страница 468: ......
Страница 493: ...Chapter 17 Service Mode...
Страница 494: ......
Страница 498: ......
Страница 690: ......
Страница 691: ...Chapter 18 Upgrading...
Страница 692: ......
Страница 694: ......
Страница 738: ...Chapter 18 18 44...
Страница 739: ...Chapter 19 Service Tools...
Страница 740: ......
Страница 741: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Oils and Solvents 19 1...
Страница 742: ......
Страница 744: ......
Страница 745: ...Jul 3 2008...
Страница 746: ......