Chapter 17
17-107
17.6.1.3 COPIER > OPTION > BODY (3/15)
0019-9601
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
T-17-52
IFAX-LIM
2
Title
Restriction on number of lines printed during IFAX reception
Purpose of use, When used
This item is used when preventing the machine from keeping on printing the attached file in case where
error mails have been received, mail parsing has failed, etc. The number of lines printed during IFAX
reception is restricted.
Precautions for use
-
Setting, adjustment and
operation procedures
0 to 999
0: No mail text is created.
999: No restrictions
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
500
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
If "0" has been set, only the header and footer will be printed out on one sheet when mail containing
only the main text and no attached files has been received.
COPIER > OPTION > BODY
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
Description
DF-BLINE
2
Title
Measures for black streaks due to dirt on the platen roller at ADF stream reading
Purpose of use, When used
This item is used when black streaks occur due to dirt on the platen roller at ADF stream reading.
Precautions for use
-
Settings and adjustment
ranges
0: Measures are not implemented. 1: Measures are implemented.
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
TEMP-TBL
1
Title
Change of the fixing regulation temperature table
Purpose of use, When used
To change the fixing regulation temperature table.
Precautions for use
-
Settings and adjustment
ranges
0: A normal fixing regulation temperature table is used. (190degC)
1: A fixing regulation temperature table for a temperature approx. 5degC lower than the normal table
is used. (185degC)
2: A fixing regulation temperature table for a temperature approx. 10degC lower than the normal table
is used. (180degC)
Unit
-
Value at time of shipment
from factory/Value
established when RAM is
cleared
0
Setting, adjustment and
operation procedures
1) Select the item to highlight it, input the setting, and press the OK key.
2) Set the main power switch to OFF and back to ON.
Related service modes
-
Additional description and
notes
-
COPIER > OPTION > BODY
The value which has been set takes effect after the main power switch has been turned OFF and back ON.
Item
Level
Description
Содержание iR3245
Страница 1: ...Jul 3 2008 Service Manual iR3245 3235 3230 3225 Series...
Страница 2: ......
Страница 6: ......
Страница 25: ...Chapter 1 Introduction...
Страница 26: ......
Страница 28: ......
Страница 64: ......
Страница 65: ...Chapter 2 Installation...
Страница 66: ......
Страница 120: ......
Страница 121: ...Chapter 3 Basic Operation...
Страница 122: ......
Страница 124: ......
Страница 128: ......
Страница 129: ...Chapter 4 Main Controller...
Страница 130: ......
Страница 132: ......
Страница 134: ...Chapter 4 4 2 F 4 1 1 5 8 9 11 14 12 3 4 10 2 13 7 15 16 17...
Страница 152: ......
Страница 153: ...Chapter 5 Original Exposure System...
Страница 154: ......
Страница 184: ......
Страница 185: ...Chapter 6 Laser Exposure...
Страница 186: ......
Страница 188: ......
Страница 197: ...Chapter 7 Image Formation...
Страница 198: ......
Страница 227: ...Chapter 8 Pickup Feeding System...
Страница 228: ......
Страница 232: ......
Страница 244: ...Chapter 8 8 12 For iR3245 3235 3230 F 8 14 1 2 3 4...
Страница 261: ...Chapter 8 8 29 10 11 12 13 14 3 1 2 4 5 4 4 1 2 3 5 4 1 2 3 5 5 4 1 2 3 5 4 1 2 3 5...
Страница 278: ......
Страница 279: ...Chapter 9 Fixing System...
Страница 280: ......
Страница 282: ......
Страница 297: ...Chapter 10 External and Controls...
Страница 298: ......
Страница 302: ......
Страница 315: ...Chapter 10 10 13 2 Uncheck SNMP Status Enabled F 10 11...
Страница 342: ......
Страница 343: ...Chapter 11 MEAP...
Страница 344: ......
Страница 346: ......
Страница 397: ...Chapter 12 e maintenance imageWARE Remote...
Страница 398: ......
Страница 400: ......
Страница 408: ......
Страница 409: ...Chapter 13 Maintenance and Inspection...
Страница 410: ......
Страница 412: ......
Страница 424: ...Chapter 13 13 12...
Страница 425: ...Chapter 14 Standards and Adjustments...
Страница 426: ......
Страница 428: ......
Страница 433: ...Chapter 14 14 5 Execute the following in Service Mode ADF white level adjustment COPIER FUNCTION CCD DF WLVL1 2 3 4...
Страница 436: ......
Страница 437: ...Chapter 15 Correcting Faulty Images...
Страница 438: ......
Страница 440: ......
Страница 465: ...Chapter 16 Self Diagnosis...
Страница 466: ......
Страница 468: ......
Страница 493: ...Chapter 17 Service Mode...
Страница 494: ......
Страница 498: ......
Страница 690: ......
Страница 691: ...Chapter 18 Upgrading...
Страница 692: ......
Страница 694: ......
Страница 738: ...Chapter 18 18 44...
Страница 739: ...Chapter 19 Service Tools...
Страница 740: ......
Страница 741: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Oils and Solvents 19 1...
Страница 742: ......
Страница 744: ......
Страница 745: ...Jul 3 2008...
Страница 746: ......