Chapter 17
17-48
TEMP-TBL
Fixing temperature regulation temperature table change
This is used to adjust the temperature of the temperature regulation for the regular paper (64 to 105g paper) uniform
speed. It improves the hot offset or fixability at the regular paper uniform speed.
Settings
-2:-10 deg C
-1:-5 deg C
0:0 deg C
+1:5 deg C
+2:+10 deg C
[Factory setting/value after clearing RAM: 0]
1
W/SCNR
For copy models, sets whether scanner is present.
Caution!
The setting value takes effect after the main power switch is turned OFF/ON.
Setting values
0: Printer model
1: Model with scanner
Reference:
The setting will automatically change to '1' upon detection of the presence of a scanner (printer model).
1
RUI-DSP
Used to select copy function in remote UI.
0: Display copy the screen in remote UI [Factory default/After RAM clear]
1: Don't display copy screen in remote UI
1
ADJ-LVL
Sets execution mode for image stabilization control performed after preset number of sheets.
Sets execution mode (adjustment set data) for forward/reverse operation of copy or print jobs and image stabilization
control done between sheets.
Reference:
Automatic adjustment control execution mode setting
This makes it possible to reduce the wait time of the users by reducing the menu items to be executed by automatic
adjustment. The automatic adjustment control is executed for Dmax control, Dhalf and ARCDAT.
However, the fluctuations in the image density increase unless the process automatic adjustment is executed from the
user mode.
0: BkDmax c Dhalf and ARCDAT are executed.
1: BkDmax c Dhalf are executed. ARCDAT is not executed.
2: ARCDAT is executed. BkDmax c Dhalf are not executed.
3: Neither BkDmax c Dhalf nor ARCDAT are executed.
[Factory setting/value after clearing RAM: 0]
1
DFDST-L1
A higher setting will increase the level of dust detection (i.e., the machine will be more sensitive in detecting dust, which
if left behind will cause thin lines in the images).
settings range
0 to 255 (0: off)
[Factory default/After RAM clear: 205]
1
DFDST-L2
A higher setting will increase the level of dust detection (i.e., the machine will be more sensitive in detecting dust, which
if left behind will cause thin lines in the images).
settings range
0 to 255 (0: off)
[Factory default/After RAM clear: 155]
1
ENVP-INT
Setting log correction interval of inner machine temperature/humidity/fixing temperature
Setting log collection interval to COPIER>FUNCTION>MISC-P>ENV-PRT and COPIER>DISPLAY>ENVRNT
Settings
0 to 480 <min>
[Factory default/After RAM clear: 60]
Reference Log is not collected when '0' is set.
1
CNTR-DSP
Selecting screen in response to the external controller
Settings
0: The external controllericon is displayed on the control panel of the copier[Factory default/After RAM clear]
(When the color image server is connected.)
1: The control panel of the copier becomes nondisplay mode
(When the control panel-mounted external controller is connected.)
1
BASE-SW
Switching from MEAP-Full model to MEAP-Base model
This is used when trouble originating in the MEAP application has occurred. The MEAP application operation can be
restricted by setting it to "0."
Settings
0: Base model
1: Full model
[Factory setting/value after clearing RAM: 1]
MEMO:
The model can be switched from "1" to "0" only.
1
SC-L-CNT
Switching of sheet size large/small threshold value in scan counter
This sets the https server port when SSL is used by HTTP of MEAP.
0: B4 size sheets are counted as the small size.
1: Letter size sheets are counted as the small size.
[Factory setting/value after clearing RAM: 0]
1
REPORT-Z
Report print attribute flag function control
Switches attribute flags added to report prints.
Setting values
0: PDL text mode
1: PDL photograph mode
2: SCAN text mode
3: SCAN photograph mode
[Factory settings and after RAM clear: 0]
1
COPIER>OPTION>BODY
Содержание iR C3380 series
Страница 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series...
Страница 2: ......
Страница 6: ......
Страница 23: ...Chapter 1 Introduction...
Страница 24: ......
Страница 26: ......
Страница 52: ......
Страница 53: ...Chapter 2 Installation...
Страница 54: ......
Страница 127: ...Chapter 3 Basic Operation...
Страница 128: ......
Страница 130: ......
Страница 136: ......
Страница 137: ...Chapter 4 Main Controller...
Страница 138: ......
Страница 160: ......
Страница 161: ...Chapter 5 Original Exposure System...
Страница 162: ......
Страница 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69...
Страница 189: ...Chapter 6 Laser Exposure...
Страница 190: ......
Страница 192: ......
Страница 206: ......
Страница 207: ...Chapter 7 Image Formation...
Страница 208: ......
Страница 256: ......
Страница 257: ...Chapter 8 Pickup Feeding System...
Страница 258: ......
Страница 262: ......
Страница 303: ...Chapter 9 Fixing System...
Страница 304: ......
Страница 306: ......
Страница 321: ...Chapter 10 Externals and Controls...
Страница 322: ......
Страница 326: ......
Страница 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled...
Страница 337: ...Chapter 10 10 11 F 10 11...
Страница 359: ...Chapter 11 MEAP...
Страница 360: ......
Страница 362: ......
Страница 401: ...Chapter 12 RDS...
Страница 402: ......
Страница 404: ......
Страница 411: ...Chapter 13 Maintenance and Inspection...
Страница 412: ......
Страница 414: ......
Страница 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4...
Страница 421: ...Chapter 14 Standards and Adjustments...
Страница 422: ......
Страница 424: ......
Страница 431: ...Chapter 15 Correcting Faulty Images...
Страница 432: ......
Страница 434: ......
Страница 459: ...Chapter 16 Self Diagnosis...
Страница 460: ......
Страница 462: ......
Страница 481: ...Chapter 17 Service Mode...
Страница 482: ......
Страница 484: ......
Страница 571: ...Chapter 18 Upgrading...
Страница 572: ......
Страница 574: ......
Страница 603: ...Chapter 19 Service Tools...
Страница 604: ......
Страница 605: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools 19 1 19 1 2 Solvents and Oils 19 2...
Страница 606: ......
Страница 609: ...Aug 29 2006...
Страница 610: ......