![Canon imageRUNNER ADVANCE C2030 Скачать руководство пользователя страница 726](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452726.webp)
8
8
8-174
8-174
Service Mode > COPIER > COUNTER > DRBL-2
Service Mode > COPIER > COUNTER > DRBL-2
COPIER > COUNTER > DRBL-1
PT-DR-C
Drum Unit (C) parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
REG-RL
Cassette 1 Pickup Unit parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
R-DOOR
Right Door Unit parts counter
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
T-8-65
■
DRBL-2
COPIER > COUNTER > DRBL-2
DF-PU-RL
Pickup Roller Unit prts cntr: DADF
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Supplement/memo
Regardless of the read mode (1-sided/2-sided), the counter is
advanced every time a sheet is fed.
DF-SP-PD
Separation Pad parts counter: DADF
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Supplement/memo
Regardless of the read mode (1-sided/2-sided), the counter is
advanced every time a sheet is fed.
LNT-TAPE
Fd Guide(Dust Colct Tape)prts cntr:DADF
Lv.1 Details
1st line: Total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Supplement/memo
Regardless of the read mode (1-sided/2-sided), the counter is