Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E614 0612 00
Title
Error in file system on the Flash PCB
Description The file system failed to be initialized properly at startup
Remedy
1. Turn OFF and then ON the main power
2. Initialize the corresponding partition (all the data in the
corresponding partition is erased)
Perform the procedure to enter service mode, Select the
following to enter 3: [1]:CHK-TYPE = 3, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
4. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
5. Replace the Flash PCB and install the system using SST or
USB
6. Replace Main Controller PCB 1
E614 0613 00
Title
Error in file system on the Flash PCB
Description Error in file system writing after startup
Remedy
1. Turn OFF and then ON the main power
2. Initialize the corresponding partition (all the data in the
corresponding partition is erased)
Perform the procedure to enter service mode, Select the
following to enter 3: [1]:CHK-TYPE = 3, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
4. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
5. Replace the Flash PCB and install the system using SST or
USB
6. Replace Main Controller PCB 1
E
Code
Detail
Code
Location
Item
Description
E614 0702 00
Title
Error in file system on the Flash PCB
Description The file system failed to be initialized properly at startup
Remedy
1. Turn OFF and then ON the main power
2. Initialize the corresponding partition (all the data in the
corresponding partition is erased)
Perform the procedure to enter service mode, Select the
following to enter 1: [1]:CHK-TYPE = 1, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
4. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
5. Replace the Flash PCB and install the system using SST or
USB
6. Replace Main Controller PCB 1
E614 0703 00
Title
Error in file system on the Flash PCB
Description I/O error occurred in the file system at startup
Remedy
1. Turn OFF and then ON the main power
2. Initialize the corresponding partition (all the data in the
corresponding partition is erased)
Perform the procedure to enter service mode, Select the
following to enter 1: [1]:CHK-TYPE = 1, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
3. Erase all partitions that can be initialized (all of erasable
partition data is erased)
Perform the procedure to enter service mode, Select the
following to enter 0: [1]:CHK-TYPE = 0, and execute the
following: [3]:HD-CLEAR = 1, and then turn OFF and ON the
power.
4. Start in safe mode and format the Flash PCB, and then
reinstall the system using SST or USB.
5. Replace the Flash PCB and install the system using SST or
USB
6. Replace Main Controller PCB 1