Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E730 100A 00
Title
PDL software error
Description Systematic fatal error occurs
Remedy
1. PDL reset processing (user mode > function settings >
printer > printer settings > utility > Reset Printer)
2. Turn OFF and then ON the power
E730 A006 00
Title
PDL communication error
Description No reply from PDL. No reply from PDL due to failure or absence
of the controller firmware
Remedy
1. PDL reset processing (user mode > function settings >
printer > printer settings > utility > Reset Printer)
2. Turn OFF and then ON the power
3. Check connection of Main Controller PCB 2
4. Reinstall the controller firmware
5. Replace Main Controller PCB 1
E730 A007 00
Title
Mismatched PDL version
Description Mismatch in version of the control software between the host
machine and the PDL
Remedy
System all format and installation
E730 B013 00
Title
PDL embedded font error
Description Broken font data
Remedy
1. Turn OFF and then ON the power
2. Reinstall the system using SST or USB
3. System all format and reinstall the system using SST or USB
E730 C000 00
Title
Initialization error
Description An error, such as failure in memory retrieval at startup, occurs
Remedy
System all format and installation
Replace Main Controller PCB 1
E730 C001 00
Title
HDD access error
Description An error occurs when accessing to the HDD
Remedy
1. Start in safe mode to format the HDD (all the data in the
HDD is erased)
2. Replace the HDD
3. Replace Main Controller PCB 2
4. Replace Main Controller PCB 1
E731 3000 00
Title
Error in Main Controller PCB 2
Description Unable to recognize the Surf board
Remedy
1. Check connection of Main Controller PCB 2
2. Replace Main Controller PCB 2
3. Replace Main Controller PCB 1
E731 3001 00
Title
Error in Main Controller PCB 2
Description Failure in Surf initialization
Remedy
1. Check connection of Main Controller PCB 2
2. Replace Main Controller PCB 2
3. Replace Main Controller PCB 1
E
Code
Detail
Code
Location
Item
Description
E731 3002 00
Title
Error in Main Controller PCB 2
Description Failure in Surf initialization
Remedy
1. Check connection of Main Controller PCB 2
2. Replace Main Controller PCB 2
3. Replace Main Controller PCB 1
E731 3015 00
Title
Error in Main Controller PCB 2
Description Although it works normally at the software side, there is no
video data into CL1-G
Remedy
1. Check connection of Main Controller PCB 2
2. Replace Main Controller PCB 2
3. Replace Main Controller PCB 1
E732 0001 00
Title
Scanner communication error
Description DDI-S communication error
Remedy
1. Check the connector connection with the scanner
2. Check the power of the scanner > Is initialization executed at
startup?
3. Replace the Reader Controller PCB, the Scanner PCB or
Main Controller PCB 2
E732 0010 00
Title
Scanner communication error
Description Vertical Synchronizing signal detection error
Remedy
1. Check the connector connection with the scanner
2. Check the power of the scanner > Is initialization executed at
startup?
3. Replace the Reader Relay PCB, the Scanner PCB or Main
Controller PCB 2
E732 9999 00
Title
Scanner communication error
Description When a scanner is detected from the printer model for the first
time (It is recorded in the history, but “Turn OFF and then ON
the power again” is displayed on the UI.)
Remedy
1. Turn OFF and then ON the power
E732 FFFF 00
Title
Scanner communication error
Description A network communication error in a development environment
is detected.
Remedy
1.Checking network connection
2.Turn OFF and then ON the main power.
E733 0000 00
Title
Printer communication error
Description A communication error between the DC Controller PCB and the
Main Controller PCB 2 is detected at startup.
Remedy
1. Turn OFF and then ON the main power.
2. Check the connection of the Flexible Cable between the DC
Controller PCB (UN9) and the Main Controller PCB 2.
3. Replace the Flexible Cable.
4. Check the power of the DC Controller PCB (UN9). (Check if
the initialization operation is executed at startup.)
5. Replace the DC Controller PCB (UN9).
6. Replace the Main Controller PCB 2.