Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Error Code
Error Code Details
E
Code
Detail
Code
Location
Item
Description
E001 0001 05
Title
Main Thermistor high temperature detection
Detection Main Thermistor 2 detected a temperature of 230 deg C or higher
for 0.1 sec or longer.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/J12) and
the Fixing Assembly (UN37/J123,UN13/J13) (trapped cable, open
circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Disconnect the connector of DC Controller PCB (UN09/J12)
and start the host machine to check the reading value of the
following: service mode > COPIER > DISPLAY > ANALOG >
FIX-C
=> When the value is 40 deg C or higher
3-1. Replace the DC Controller PCB (UN09)
=> When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E001 0002 05
Title
Center Thermistor high temperature detection
Detection Main Thermistor 1 detected a temperature of 283 deg C or higher
for 0.1 sec or longer.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Disconnect the connector of DC Controller PCB (UN09/ J12)
and start the host machine to check the reading value of the
following: service mode > COPIER > DISPLAY > ANALOG >
FIX-E
=> When the value is 40 deg C or higher
3-1. Replace the DC Controller PCB (UN09)
=> When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E
Code
Detail
Code
Location
Item
Description
E001 0003 05
Title
Edge Thermistor high temperature detection
Detection Sub Thermistor 1 detected a temperature of 283 deg C or higher
for 0.1 sec or longer.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Disconnect the connector of DC Controller PCB (UN09/ J12)
and start the host machine to check the reading value of the
following: service mode > COPIER > DISPLAY > ANALOG >
FIX-E2
=> When the value is 40 deg C or higher
3-1. Replace the DC Controller PCB (UN09)
=> When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR
E001 0004 05
Title
Edge Thermistor high temperature detection
Detection Sub Thermistor 2 detected a temperature of 283 deg C or higher
for 0.1 sec or longer.
Remedy Fixing Assembly error, Fixing temperature detection error
1. Check failure between the DC Controller PCB (UN09/ J12) and
the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable,
open circuit, connector disconnection).
-> Replace the part in the case of trapped cable/open circuit
2. Disconnect the connector of DC Controller PCB (UN09/ J12)
and start the host machine to check the reading value of the
following: service mode > COPIER > DISPLAY > ANALOG >
FIX-E3
=> When the value is 40 deg C or higher
3-1. Replace the DC Controller PCB (UN09)
=> When the value is lower than 40 deg C
3-2. Replace the Fixing Assembly
NOTE: After performing the above remedy work, go through the
following to clear the error: COPIER > FUNCTION > CLEAR >
ERR