Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E025 0200 05
Title
Toner Supply Motor (C) lock detection
Detection After turning ON the motor, the rotation sensor does not detect
although a specified period of time has passed.
Remedy Overload of the motor or motor failure
1. Check conduction of FU9 on the DC Controller PCB (UN09).
2. Check the harness/connector between the DC Controller PCB
(UN09/J24) and PS08.
3. Replace the DC Controller PCB (UN09)
4. Check the Hopper Unit (C).
5. Replace the Hopper Unit (C).
E025 0210 05
Title
Toner Container Motor (C) lock detection
Detection After turning ON the motor, current value is 2.5V or higher for a
specified consecutive period of time.
Remedy Overload of the motor or motor failure
1. While the Toner Bottle (C) is removed,
COPIER > FUNCTION > PART-CHK > MTR; and move M11
When the motor works,
2-1. Check if the Toner Bottle (C) is installed
3-1. Check the Hopper Unit (C)
When the motor does not work,
2-2. Check the harness/connector between the DC Controller
PCB (UN09) and the Toner Container Motor (C) (M12)
3-2. Check conduction of FU3 in the DC Controller PCB (UN09)
4-2. Replace the DC Controller PCB (UN09)
5-2. Replace the Hopper Unit (C)
E025 0220 05
Title
Detection of short-circuit with Toner Container Motor (C)FET
Detection After turning OFF the motor, current value is 1.5V or higher for a
specified consecutive period of time.
Remedy Error in element in the DC Controller PCB
1.Replace the DC Controller PCB (UN09)
E025 0230 05
Title
Detection of short-circuit with Toner Container Motor (C) GND
Detection After the Motor was turned ON, the current value (AD value) is
equal to or lower than 0.5h (0.06V: Motor current 0.06A) for 5
consecutive sec.
Remedy Short-circuit failure of the Toner Bottle Motor or error in element in
the DC Controller PCB
1. Check the harness between the DC Controller (UN09/J24) and
the Toner Container Motor (C) (M11)
2. Replace the DC Controller PCB (UN09)
3. Replace the Hopper Unit (C)
E
Code
Detail
Code
Location
Item
Description
E025 0300 05
Title
Toner Supply Motor (Bk) lock detection
Detection The Rotation Sensor does not detect rotation although 5 sec has
passed since the motor was turned ON
Remedy Overload of the motor or motor failure
1. Check conduction of FU9 on the DC Controller PCB (UN09).
2. Check the harness/connector between the DC Controller PCB
(UN09/J26) and PS09
3. Replace the DC Controller PCB (UN09)
4. Check the Hopper Unit (Bk).
5. Replace the Hopper Unit (Bk).
E025 0310 05
Title
Toner Container Motor (Bk) lock detection
Detection After turning ON the motor, current value is 2.5V or higher for a
specified consecutive period of time.
Remedy Overload of the motor or motor failure
1. While the Toner Bottle (Bk) is removed,
COPIER>FUNCTION>PART-CHK>MTR; and move M13
When the motor works,
2-1. Check if the Toner Bottle (Bk) is installed
3-1. Check the Hopper Unit (Bk)
When the motor does not work,
2-2. Check the harness/connector between the DC Controller
PCB (UN09) and the B Toner Container Motor (Bk)(M13)
3-2. Check conduction of FU3 in the DC Controller PCB (UN09)
4-2. Replace the DC Controller PCB (UN09)
5-2. Replace the Hopper Unit (Bk)
E025 0320 05
Title
Detection of short-circuit with Toner Container Motor (Bk)FET
Detection After turning OFF the motor, current value is 1.5V or higher for a
specified consecutive period of time.
Remedy Error in element in the DC Controller PCB
1.Replace the DC Controller PCB (UN09)
E025 0330 05
Title
Detection of short-circuit with Toner Container Motor (Bk) GND
Detection After the Motor was turned ON, the current value (AD value) is
equal to or lower than 0.5h (0.06V: Motor current 0.06A) for 5
consecutive sec.
Remedy Short-circuit failure of the Toner Bottle Motor or error in element in
the DC Controller PCB
1. Check the harness between the DC Controller (UN09/J26) and
the Toner Container Motor (Bk) (M13)
2. Replace the DC Controller PCB (UN09)
3. Replace the Hopper Unit (Bk)
T-7-5