E
Code
Detail
Code
Location
Item
Description
E020 1250 05
Title
Abnormal detected patch reading value
Detection Dark patch although setting 0 for the patch level (unable to fit in
the target between 550 and 640)
Remedy 1. Clean the scanner’s window.
2. Use your hand to check if the shutter of the Registration Patch
Sensor Unit can be open.
3. Check if the window of the Patch Sensor (UN43/ UN44) is
soiled.
4. Check scar on the ITB.
5. Check movement of the Registration Shutter Solenoid (SL02).
COPIER > FUNCTION > PART-CHK > SL to move SL02
6. Check the harness/connector between the DC Controller PCB
(UN09/J12) and the Patch Sensors (UN43/J4007, UN44, J4006).
7.Replace the Drum Unit (C)
8.Replace the Registration Patch Sensor Unit
9 Replace the ITB Unit.
10. Check conduction of the fuses (FU5, FU8) in the DC
Controller PCB (UN09).
11. Replace the Primary Transfer High Voltage PCB (UN04)
12. Replace the Developing High Voltage PCB (UN07)
13. Replace the Primary Charging High Voltage PCB (UN06)
14. Replace the Auxiliary High Voltage PCB (UN08)
15. Replace the Replace the DC Controller PCB (UN09)
E
Code
Detail
Code
Location
Item
Description
E020 1260 05
Title
Abnormal detected patch reading value
Detection Light patch although setting 7 for patch level (unable to fit in the
target between 550 and 640)
Remedy 1. Check the patch shape.
2. Clean the high voltage contact point with dry wiping or air
blower.
3. Check the harness/connector between the DC Controller
(UN09) and the High Voltage PCB.
Between the DC Controller PCB (UN09/ J21) and the Primary
Charging High Voltage PCB (UN06/ J441, J442)
Between the DC Controller PCB (UN09/ J21, J22) and the
Developing High Voltage PCB (UN07/ J451, J452)
Between the DC Controller PCB (UN09/ J19) and the Auxiliary
High Voltage PCB (UN08/J461, J462)
Between the DC Controller PCB (J205) and the Primary Transfer
High Voltage PCB (UN04/J1001)
4. Replace the Drum Unit (C)
5. Replace the Registration Patch Sensor Unit
6. Replace the ITB Unit.
7. Check conduction of the fuses (FU5, FU8) in the DC Controller
PCB (UN09).
8. Replace the Primary Transfer High Voltage PCB (UN04)
9. Replace the Developing High Voltage PCB (UN07)
10. Replace the Primary Charging High Voltage PCB (UN06)
11. Replace the Auxiliary High Voltage PCB (UN08)