![Canon imageRUNNER ADVANCE C2030 Скачать руководство пользователя страница 482](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452482.webp)
7
7
7-8
7-8
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
E
Code
Detail
Code
Location
Item
Description
E010 0001 05
Title
ITB Motor startup error
Detection Within a specified period of time from the startup, the speed fails
to be OK.
Remedy Possible cause is overload or rotation failure of the motor due to
an electrical trouble
1. Check the Main Drive Unit (turn the unit by hand to see if it
rotates)
Replace the Main Drive Unit when the unit failed to rotate
When the unit rotates
2. Check failure of the harness between the ITB Motor (M02/
J6027) and the DC Controller PCB (UN09/ J210W) (trapped
cable, open circuit, connector disconnection)
3. Check conduction of the fuse (FU4) in the DC Controller PCB
(UN09)
When the fuse is not blown out
4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit
When the fuse is blown out
4-2. Replace the DC Controller PCB (UN09)
E010 0002 05
Title
ITB Motor speed error
Detection ITB Motor speed error
Remedy Possible cause is overload or rotation failure of the motor due to
an electrical trouble
1. Check the Main Drive Unit (turn the unit by hand to see if it
rotates)
Replace the Main Drive Unit when the unit failed to rotate
When the unit rotates
2. Check failure of the harness between the ITB Motor (M02/
J6027) and the DC Controller PCB (UN09/ J210W) (trapped
cable, open circuit, connector disconnection)
3. Check conduction of the fuse (FU4) in the DC Controller PCB
(UN09)
When the fuse is not blown out
4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit
When the fuse is blown out
4-2. Replace the DC Controller PCB (UN09)
E
Code
Detail
Code
Location
Item
Description
E010 0003 05
Title
ITB Motor lock detection
Detection Within a specified period of time from the startup, signal is not
received.
Remedy Possible cause is overload or rotation failure of the motor due to
an electrical trouble
1. Check the Main Drive Unit (turn the unit by hand to see if it
rotates)
Replace the Main Drive Unit when the unit failed to rotate
When the unit rotates
2. Check failure of the harness between the ITB Motor (M02/
J6027) and the DC Controller PCB (UN09/ J210W) (trapped
cable, open circuit, connector disconnection)
3. Check conduction of the fuse (FU4) in the DC Controller PCB
(UN09)
When the fuse is not blown out
4-1. Replace the ITB Motor (M02)
5-1. Replace the DC Controller PCB (UN09)
6-1. Replace the Main Drive Unit
When the fuse is blown out
4-2. Replace the DC Controller PCB (UN09)
E012 0001 05
Title
CL Drum Motor speed error
Detection Within a specified period of time from the startup, the speed fails
to be OK.
Remedy Possible cause is overload or rotation failure of the motor due to
an electrical trouble
1. Check the Main Drive Unit (turn the unit by hand to see if it
rotates)
Replace the Main Drive Unit when the unit failed to rotate
When the unit rotates
2. Check failure of the harness between the Motor (M04/ J6025)
and the DC Controller PCB (UN09/ J210W)
(trapped cable, open circuit, connector disconnection)
3. Check conduction of the fuse (FU7) in the DC Controller PCB
(UN09)
When the fuse is not blown out
4-1. Replace the Drum Motor (M04)
5-1. Replace the DC Controller PCB (UN09)
When the fuse is blown out
4-2. Replace the DC Controller PCB (UN09)