![Canon imageRUNNER ADVANCE C2030 Скачать руководство пользователя страница 144](http://html2.mh-extra.com/html/canon/imagerunner-advance-c2030/imagerunner-advance-c2030_service-manual_3056452144.webp)
2
2
2-110
2-110
Process/Operation > External Auxiliary System > Power Supply Control > Energy Saving Function
Process/Operation > External Auxiliary System > Power Supply Control > Energy Saving Function
The Alarm Service is set to within 12 minutes.
• * When one of the following is being executed, the Alarm Service (Time) is set.
• - Time setting for ON/OFF of the Memory Lock
• User Mode > Function Settings > Receive/Forward > Common Settings > Fax/I-Fax Inbox >
Memory Lock Start Time
• User Mode > Function Settings > Receive/Forward > Common Settings > Fax/I-Fax Inbox >
Memory Lock End Time
• - Output of the scheduled report
• User Mode > Function Settings > Send > Common Settings > Communication Management
Report > Specify Print Time (when not set to "Off")
• User Mode > Function Settings > Send > Fax Settings > Fax Activity Report > Specify Print
Time (when not set to "Off")
• User Mode > Management Settings > Device Management > Device Information Delivery
Settings > Communication Log > Specify Print Time (when not set to "Off")
• - Scheduled Transmission Setting (Fax, Send)
• - POP settings
• User Mode > Function Settings > Send > E-Mail/I-Fax Settings > Network Settings > Next >
POP Issue Interval (when not set to "0")
• DHCP Setting (The interval is specified by the server)
• E-RDS Setting (The interval is specified by the server)
• SNTP Setting (The interval is specified by the server)
• Auto delivery of device information
• Scheduled specified printing of web browser
• Time specified backup of Inbox document
• The auto sleep timer is running (and for the time set by User Mode > Preferences > Timer/
Energy Settings > Weekly Timer Settings).
• The sleep mode exit timer is running (for 15 seconds after exiting DEEP SLEEP)."
• The network timer is running (and for the number of seconds set by Service Mode (Level 2) >
COPIER > OPTION > NETWORK > WUEN-LIV.)
• The wake up timer is running (for 10 minutes after receiving a wake up packet).
• The hard disk drive protection timer is running (for 12 minutes after exiting from DEEP SLEEP
and the HDD is powered ON. However, after a printing, scanning, and fax job is completed,
this timer is disabled.)
• The after linkup timer is running (for 1 minute after the machine is powered ON and the
communication with the network is started).
• The sleep notification timer is running (for 10 minutes after notifying the network module of
entering DEEP SLEEP. However, when the network module responds, this timer is disabled).
T-2-71