Parameters
Home screen
The voltage setting value under CV mode
The current setting value under CC mode.
The power setting value under CP mode.
The resistance setting value under CR mode.
The voltage value and current value under CV+CC mode.
The voltage value and current value under CV+CR mode.
The current value and resistance value under CC+CR.
The V, I, P, R setting value under CV+CC+CP+CR mode.
The voltage setting value under Battery Sim. mode.
Config Menu
Run mode
The status of Von function, mode and level.
You can do the save and recall operations by the following two methods.
•
Press the composite keys
[Shift]+
(Save) to save the parameters.
Press the composite keys
[Shift]+
(Recall) to recall the parameters.
•
Long press
to save the paramenters, and long press the
to recall
the parameters.
•
SCPI commands : *SAV and *RCL
Save Operation
1. Press composite keys
[Shift]+
(Save) or long press
to enter the
save parameter interface.
Save File = 1
2. Rotate the knob to enter the number 1 to 10 and set the storage location,
press
[Enter]
to save.
Recall Operation
1. Press the composite keys
[Shift]+
(Recall) or long press
to enter
the recall parameter interface.
Recall File = 1
12.000V