7.4.8 View the System Information
This menu item is used to view the system information of the instrument. The
procedures to view the system information are as follows.
1. Press composite keys
[Shift]+[P-Set]
(System) to enter the System menu.
2. Rotate the knob to select
System Info
and press
[Enter]
to confirm.
3. Rotate the knob and view the system information.
Name
Description
Model
The instrument model
ArmVer
The control board version
InvDspVer
The DSP version
FpgaVer
The Fpga version
CommVer
The communication board version
SN
The serial number
Mac
The firmware address
Last Cal
Last calibration date
Start Time
Instrument running time
4. Press
[Esc]
to exit.
7.5 Measuring the DUT Temperature
This series instrument features temperature measuring terminals (Temp, GND),
is used to measure the DUT temperature. The operation procedures as
following:
1. Connecting the test line
a. Loosen the screws of the measuring temperature terminals, and insert
the thermocouple. Re-tighten the screws.
b. Connecting the other end of thermocouple to DUT.
2. Observe the information
a. Press the composite keys
[Shift]+[P-set]
(System) to enter the system
menu.
b. Rotate the knob to select the
External Meter
and press
[Enter]
to
confirm.
c. The DUT temperature and total historical regenerative power are
displayed on screen.
1
:
UUT Temp
Copyright © Itech Electronic Co., Ltd.