1. Configure the channel number of each instrument. Please refer to
for detailed introduction.
2. Connect the instruments according to the above diagram.
a. Connect system bus interfaces. Before connecting the system bus, be
sure that the instrument is single mode.
b. Connect the DUTs. Refer to
2.5 Connecting the Device Under Test
for more information about connection methods.
3. After finishing connection, configure one power supply as a master unit.
a. Press
[Shift]+[Save]
(System) composite keys to enter the system menu
interface.
b. Use left and right keys or rotate the knob to select
Parallel
and press
[Enter]
key to make the parameter in modification.
c. Rotate the knob to select
Master
and press
[Enter]
key to confirm.
d. Set
Master group
to A and press
[Enter]
key to confirm.
e. Set
Master Total
to 3 and press
[Enter]
key to confirm.
At this time the screen displays “Search Slave...”, it will return
normally automatically after configuration.
4. Configure the remaining two units as slave units.
a. Press
[Shift]+[Save]
(System) composite keys to enter the system
menu.
b. Use left and right keys or rotate the knob to select
Parallel
and press
[Enter]
key to make the parameter in modification.
c. Rotate the knob to select
Slave
and press
[Enter]
key to confirm.
d. Set
Slave group
to A and press
[Enter]
key to confirm.
Copyright © Itech Electronic Co., Ltd.