Parameter
Default Value
OCP Level
Max
OCP Dealy
10.00S
OPP Mode
Off
OPP Level
Max
OPP Delay
10.00S
UVP Mode
Off
UVP Level
0.00V
UVP Delay
10.00S
UVP Warm
30.00S
UCP Mode
Off
UCP Level
0.000A
UCP Delay
10.00S
UCP Warm
30.00S
7.4.7 Observe the DUT Temperature and Total Historical
Regenerative Power
This series instrument supports measuring DUT temperature and total historical
regenerative power. User can observe the information under the system menu,
and also the user can set the menu to display the information on the home
screen. The procedure as following:
1. Press the composite keys
[Shift]+[P-set]
(System) to enter the System
menu.
2. Rotate the knob to select
Ext-Meter Disp
and press
[Enter]
to confirm.
3. Rotate the knob to select
On
or
Off
and press
[Enter]
to confirm.
4. Press
[Esc]
to exit. the home screen as below.
12.000V
10.000A
38.0
℃
1000.0Wh
User can press the V-set and I-set and set voltage and current value, and
the instrument will return to the home screen automatically after activity
on the front panel has ceased.