Boiler installation
8
Logano G215 WS - We reserve the right to make any changes due to technical modifications.
36
8.2
Making the water connections
8.2.1 Connecting central heating flow and return
z
Connect the central heating return to connector RK.
z
Connect the central heating flow to connector VK.
8.2.2 Connecting the safety flow and return
We recommend the connection of a boiler safety set
(accessory) or an air-vent valve (accessory) to
connector VSL.
8.2.3 DHW cylinder connection
z
Connect the DHW cylinder return to connector RS.
z
Connect the DHW cylinder flow either at VS1 or VS2.
z
Seal off the surplus VS connector.
CAUTION!
SYSTEM DAMAGE
through leaking connections.
z
Connect the pipes without stress to the
boiler connections.
Fig. 52 Connecting the heating flow and return
RK
VK
USER NOTE
We recommend the on-site installation of a
dirt trap (accessory) into the central
heating return to prevent contamination on
the water side.
VSL:
Flow safety line
VK:
Boiler flow
RK:
Boiler return
VS:
DHW cylinder flow
RS:
DHW cylinder return
EL:
Drain
Fig. 53 Connecting the air vent valve to the safety flow
VSL
CAUTION!
SYSTEM DAMAGE
through the connection of incorrect
components to connector VSL.
z
Never connect a summer line, DHW
cylinder or another heating circuit to
VSL.
Fig. 54 DHW cylinder, connecting
RS2
RS1
VS1
VS2
Содержание Logano G215 WS
Страница 58: ...Index 13 Logano G215 WS We reserve the right to make any changes due to technical modifications 58...
Страница 59: ...Notes Logano G215 WS We reserve the right to make any changes due to technical modifications 59...
Страница 60: ...Notes Logano G215 WS We reserve the right to make any changes due to technical modifications 60...
Страница 61: ...Notes Logano G215 WS We reserve the right to make any changes due to technical modifications 61...