Technical data
and start-up
EVB1-350/400-40-HP
94
ERROR TYPE
ERROR CODE
(HEX / DEC)
CAN SIGNAL
DESCRIPTION
CAUSE
SET
CONDITION
RESET CONDITION
TE
0x0002
2
BMS_TErr_OverTemperature
Temperature above
the max. value
CCU_T_HIGH > 46°C [10.3]
and
I2 t of under -2 A [11.3] >
12000 A
2
s
or
CCU_T_HIGH > 56°C [10.7]
and
BATT_Current_Act <
2 A [11.2]
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
BMS_MODE_OTP = 0
TE
0x0001
1
BMS_TErr_UnderTemperature Temperature under
the min. value
CCU_T_LOW < 9°C [10.6]
and
I2t of under -2 A [11.3] >
12000 A
2
s
or
CCU_T_LOW < -11°C
[10.10]
and
BATT_Current_Act
>2 A [11.2]
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
BMS_MODE_UTP = 0
W
0x8000
32768
BMS_War_CanOff
CAN controller sets
the BUS OFF bit
CAN controller sets the BUS
OFF bit
0
Not set condition
W
0x4000
16348
BMS_War_CanRx
CAN receive error
counter > 127
CAN receive error counter >
127
0
Not set condition
W
0x2000
8192
BMS_War_CanTx
CAN transmit error
counter > 127
CAN transmit error counter >
127
0
Not set condition
W
0x1000
4096
BMS_War_CanValue
Received CAN value
reduced to
acceptable range
CAN value outside valid
range
0
Not set condition
W
0x0800
2048
BMS_War_Watchdog
Watchdog overflow
(32.64 ms); the
internal watchdog is
refreshed every
0.66 ms
Watchdog overflow
(32.64 ms); the internal
watchdog is refreshed every
0.66 ms
0
Not set condition
W
0x0400
1024
BMS_War_EEPROM
Data could not be
saved in the
EEPROM
Error while writing into the
EEPROM
0
Start-up
W
0x0200
512
BMS_War_bit6
-
-
0
Not set condition
W
0x0100
256
BMS_War_bit7
-
-
0
Not set condition
W
0x0080
128
BMS_War_OverCharge
The alert threshold
has been surpassed
Highest cell voltage [Ri] >
4.1 V [6.3]
0
Not set condition
W
0x0040
64
BMS_War_OverDischarge
The alert threshold
has been surpassed
Lowest cell voltage [Ri] <
3.4 V [6.10]
0
Not set condition