19
Technical data
and start-up
EVB1-350/400-40-HP
3.4.3
Monitoring of Cell Voltages
In the BMS the two highest and the two lowest cell voltages are measured at intervals of 1 ms. These are relayed
with the CAN signal
CCU_V
. Additionally every cell is measured in series at a frequency of around 1 kHz. The
values measured are identified with an index and relayed one after another via CAN
CCU_Cell
. The following
factors are included in this index:
Number of cells (
CCU_Number
)
Current index (
CCU_Index
)
Associated voltage (
CCU_V
)
Associated Temperature (
CCU_T
)
The maximum and minimum voltage are averaged over a time frame of 100 ms and are relayed with the CAN
signal
CCU_max
(
CCU_V_LOW_PEAK / CCU_V_HIGH_PEAK
). For each voltage measurement, an internal
resistance of 1 mohm per cell is factored in.