Technical data
and start-up
EVB1-350/400-40-HP
50
7.3.9
Pin 13 PRO
INSTRUCTION
The programming of the wrong firmware can lead to the damage of the battery!
So the programming may only be carried out after consultation with the company BRUSA Elektronik
AG!
INFORMATION
This pin is only activated for the programming of a new firmware (pin 13
PRO
=
high
). Pin 3
EN
must
also be
high
for this.
In normal operation, pin 13
PRO
may not be wired or it must be directly connected with terminal 31.
An open circuit can lead to a reset of the battery!
The voltage range for pin 13
PRO
=
high
is between 9 - 15 V.
Internal wiring
1,0V
3,3V
4
7
n
F
Pin 13 PRO
2
2
0
p
F
Schmitt
Trigger
22k
Ω
10
k
Ω
33
V
4
,7
V
As soon as pin 13
PRO
is
high
, the following processes are activated:
The battery is stopped (reset) if it is in operation.
The programming can now be carried out via the serial interface.
10.6 Carrying Out Firmware Updates