7.3.10 Pin 16 RFK1, Pin 17 RFK2, Pin 18 RFKC
INFORMATION
These pins carry out redundant monitoring of each of the contactors from the outside via a switch in
the contactor. This way, whether the contactors are open or closed can be constantly monitored. The
signals can be analysed by the customer accordingly for this monitoring.
Internal wiring
1
0
nF
Pin 17 RFK2
1
0
nF
Pin 18 RFKC
1
0
nF
Pin 16 RFK1
S
2
Ma
in
c
onta
c
tor
B
-
N
orm
a
ll
y
open
S
3
Ma
in
c
onta
c
tor
B+
N
orm
a
ll
y
open
HV+
HV-
max. contact current 300 mA @ 12 V
min. contact current 100 mA @ 12 V
(Tyco KILOVAC EV200 Series)