81
Technical data
and start-up
EVB1-350/400-40-HP
12 NLG
NO.
NAME
INIT
DESCRIPTION
12.8
Balancing
0.10 V
Max. cell voltage difference
(Max Cell Voltage
– V_diff = V_min)
13 FAN&PUMP
NO.
NAME
INIT
DESCRIPTION
13.1
Step1: temp off
25°C
Step 1 switch-off temperature
13.2
Step1: temp on
30°C
Step 1 switch-on-temperature
13.3
Step1: fan
50%
Step 1 fan power in percent
The fan power depends on the input voltage at pin 2
AUX
13.4
Step1: ext. fan
50%
Step 1 external fan power in percent
13.5
Step1: pump
99%
Step 1 external water pump power in percent
13.6
Step2: temp off
30°C
Step 2 switch-off temperature
13.7
Step2: temp on
35°C
Step 2 switch-on temperature
13.8
Step2: fan
99%
Step 2 fan power in percent
The fan power depends on the input voltage at pin 3
EN
13.9
Step2: ext. fan
99%
Step 2 external fan power in percent
13.10
Step2: pump
99%
Step 2 external water pump power in percent
Содержание EVB1-350-40-HP
Страница 33: ...33 Technical data and start up EVB1 350 400 40 HP 6 6 1 EVB1 400 350 40 HP Block Circuit Diagram...
Страница 42: ...Technical data and start up EVB1 350 400 40 HP 42 6 9 2 Control via Terminal 15 with Driving via CAN...