Temperature Measurement / Temperature Monitoring
The temperature measurement takes place over one sensor per cell packet. In this, temperature is measured over
18 sensors in total. The highest (
CCU_T_HIGH
), the lowest (
CCU_T_LOW
) and the average temperature value
(
BATT_T_AVERAGE
) can be emitted as an output value. Along with the voltage value, the temperature value per
cell block is emitted with the relevant index in the message
CCU_Cell
(
CCU_T
). In each case, the limit is
CCU_T_HIGH.
The temperature monitoring takes place in three steps:
Step 1:
Warning
If a defined temperature value is reached or exceeded, the warning message or CAN signal
BMS_War_OverTemperature
or
BMS_War_UnderTemperature
will be emitted.
Step 2:
Reaching of the Limit
If the defined limit is reached or exceeded, this signifies a charging current of 0 A set by derating
(
BATT_CurrentDischargeMax / BATT_CurrentChargeMax
).
The CAN signal
BMS_MODE_OTP
or
BMS_MODE_UTP
is emitted.
Step 3:
Reaching of the maximum value:
If the defined maximum value is reached or exceeded, the battery immediately disconnects from the DC
intermediate circuit, when a current flows.
The error message or the CAN signal
BMS_TErr_OverTemperature / BMS_TErr_UnderTemperature
is
emitted.