Technical data
and start-up
EVB1-350/400-40-HP
ERROR TYPE
ERROR CODE
(HEX / DEC)
CAN SIGNAL
DESCRIPTION
CAUSE
SET
CONDITION
RESET CONDITION
TE
0x1000
4096
BMS_TErr_bit3
-
-
0
At new Kl_15 start up
TE
0x0800
2048
BMS_TErr_bit4
-
-
0
At new Kl_15 start up
TE
0x0400
1024
BMS_TErr_bit5
-
-
0
At new Kl_15 start up
TE
0x0200
512
BMS_TErr_VoltageDivCCU
Total voltage
measurement differs
from the sum of the
cell voltages
BCM_U1 or BCM_U2
deviation of
BATT_Voltage_Act of more
than 10 V [11.1]
5000 ms
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
not set condition
TE
0x0100
256
BMS_TErr_VoltageDivBCM
Voltage
measurement before
and after contactor
are too different from
one another
Deviation of BCM_U1 from
BCM_U2 of more than
10 V [11.1]
5000 ms
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
not set condition
TE
0x0080
128
BMS_TErr_bit8
-
-
0
At new Kl_15 start up
TE
0x0040
64
BMS_TErr_ChargeI2t
The Charge load
duration of the battery
is too long
I2 t of under 120A [6.6] <
64000 A
2
s [6.7, 6.9]
0
At new Kl_15 start up
TE
0x0020
32
BMS_TErr_CellVoltageDiff
Too great a
difference between
the cell voltages with
too large a current
flow
CCU_V_HIGH -
CCU_V_LOW >400 mV [5.5]
and
BCM_A > 20 A [5.6]
and
BMS_War_OverDischarge =
0
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
BMS_War_CellVoltag
eDiff = 0
TE
0x0010
16
BMS_TErr_NLG
NLG reports fault
Report received from NLG
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
Report received from
NLG
TE
0x0008
8
BMS_TErr_FuseI2t
The peak load
duration of the battery
is too long
I2 t of over 600A [7.1] >
10000 A
2
s [7.3]
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
I2t = 0
TE
0x0004
4
BMS_TErr_DischargeI2t
The discharge load
duration of the battery
is too long
I2 t of over 320 A [6.15] >
784000 A
2
s [6.16, 6.18]
0
At new Kl_15 start up
OR BMS_State =
BMS_SHUTDOWN
AND
I2t = 0