10.3.1 Configurable Parameters
INFORMATION
In this chapter, only the configurable parameters are listed. The complete CAN matrix is a part of the
customer package.
1 GENERAL PARAMETERS
NO.
NAME
INIT
DESCRIPTION
1.4
DBG COM Master ID
0x400
ID of battery Tx message
1.5
DBG COM Slave ID
0x401
ID of battery Tx message
3 CAN1 PARAMETERS
NO.
NAME
INIT
DESCRIPTION
3.1
Rx CMD
0x000
ID of message
0 = no function
BMS is switched on via terminal 15
3.2
Tx BCM
0x200
ID of message
0 = not sent
3.3
Tx BCM_Ah
0x201
ID of message
0 = not sent
3.4
Tx BCM_Wh
0x202
ID of message
0 = not sent
3.5
Tx CCU_V
0x300
ID of message
0 = not sent
3.6
Tx CCU_Max
0x301
ID of message
0 = not sent
3.7
Tx CCU_CELL
0x302
ID of message
0 = not sent
3.8
Tx BMS_Status
0x100
ID of message
0 = not sent
3.9
Tx BATT_Act
0x110
ID of message
0 = not sent
3.10
Tx BATT_Range
0x111
ID of message
0 = not sent
3.11
Rx NLG5_ST
0x610
ID of message NLG5_ST
0 = not sent
3.12
Tx NLG5_CTL
0x618
ID of message NLG5_CTL
0 = not sent
3.13
Rx NLG5_ACT_I
0x611
ID of message NLG5_ACT_I
0 = not sent
3.14
Baud rate
500 (1000)
---
3.15
Sampling point
68.75
---
12 NLG
NO.
NAME
INIT
DESCRIPTION
12.1
Mains: max. current
16.0 A
Max. current from the 240 V AC network
12.2
Phase1: C-rate
0.5 C
Max. charging current of phase 1
12.3
Phase1: max. cell voltage
4.15 V
Max. cell voltage of phase 1
12.4
Phase1: cut-off current
2.0 A
Switch to phase 2 as soon as the current has fallen below this level
12.5
Phase2: max. current
2.0 A
Max. charging current of phase 2
12.6
Phase2: max. Ah
0.5 Ah
Max. charging in phase 2
12.7
Phase2: max. time
180.0 min
Max. charging time of phase 2