![Brusa EVB1-350-40-HP Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/brusa/evb1-350-40-hp/evb1-350-40-hp_technical-data-and-start-up_2821421018.webp)
Technical data
and start-up
EVB1-350/400-40-HP
18
The current monitoring takes place in three steps:
Step 1:
Warning and Limit Reached
As soon as the limit is reached or exceeded, the warning message or CAN signal
MS_War_OverCurrentCharge
or
BMS_War_OverCurrentDischarge
is emitted.
In addition, the CAN signal
BMS_MODE_CP
is emitted.
Step 2:
Limit Reached, Peak Current Duration Exceeded
The maximum discharging current (600 A) can run for a duration of around 10 s. This produces a current field
output (I
2
t) of
784’000 A
2
s.
(I
peak
– I
cont
)
2
* t
= I
2
t
(600A
– 320A)
2
* 10s
=
784‘000A
2
s
If this value is reached, the derating mode enters immediately and reduces the discharge current gradually
down to <320 A (discharge cont.).
With a discharge current <320 A, the battery can recover. The longer the recovery period, the longer it can
then be run again with the maximum discharge current (max. 10 s).
It is recommended that the derating of the current be followed (
BATT_CurrentDischargeMax
).
If the current field output is reached or exceeded (I
2
t), the battery automatically disconnects from the DC
intermediate circuit and sends an error report or the CAN signal
BMS_TErr_DischargeI2t
.
Step 3:
Maximum Current Exceeded
If the current exceeds a level of 630 A or falls below -130 A, the battery is immediately disconnected from the
DC intermediate circuit.
The CAN signal
BMS_Err_CurrentCharge / BMS_Err_CurrentDischarge